A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ... -
A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1 beta in human serum and saliva
(Elsevier Science Bv, 2018)In this study, we constructed a new and sensitive ITO based electrochemical immunosensor for detection of interleukin 1 beta(IL-1 beta), a cancer biomarker found in serum and saliva. 6-phosphonohexanoic acid (PHA) was used ... -
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ... -
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ... -
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
(Elsevier Advanced Technology, 2018)A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ... -
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ... -
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ... -
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ... -
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ... -
A label-free and sensitive impedimetric immunosensor for TNF ? biomarker detection based on epoxysilane-modified disposable ITO-PET electrode
(Taylor and Francis Ltd., 2020)The present study constructed a simple and cost-effective electrochemical immunosensor based on 3-glycidoxypropyltriethoxysilane (GPTES) monolayer coated indium tin oxide-polyethylene terephthalate (ITO-PET) electrode for ... -
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
(Elsevier B.V., 2020)A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ... -
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
(Elsevier B.V., 2021)An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ... -
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ... -
Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
(Elsevier B.V., 2021)In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were ... -
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ...