A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
Özet
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide electrode. This conjugated polymer was synthesized to fabricate this immunosensor for the first time and it offered a good biosensing platform for anti-IL 1? antibody immobilization due to epoxy groups present on the side groups of the polymer. Furthermore, the epoxy-substituted polythiophene polymer coated indium tin oxide electrode was used for the determination of IL 1? antigen for the first time. Electrode fabrication stages were characterized by using electrochemical (electrochemical impedance spectroscopy and cyclic voltammetry) and morphological (scanning electron microscopy and atomic force microscopy) techniques. Under optimum experimental conditions, impedimetric responses of the immunosensor increased with the increasing of IL 1? antigen concentration, and the proposed immunosensor displayed a wide linear detection range from 0.01 pg/mL to 5.5 pg/mL with a detection limit of 3.4 fg/mL. The proposed immunosensor exhibited outstanding performance including excellent reproducibility, good repeatability, high selectivity and long storage stability. With the advantages of simple operation, low-cost fabrication and label-free format, the suggested immunosensor was expected to have potential applications for IL 1? cancer biomarker detection. © 2019 Elsevier B.V.
Cilt
144İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
Aydın, Elif Burcu (Elsevier B.V., 2020)A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ... -
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2021)An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ...