A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
Özet
An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. The EpxS-PPyr polymer was a promising matrix material to increase the loading capacity of immunosensor owing to its large surface area and abundance of epoxy groups. EpxS-PPyr polymer was synthesized by an esterification reaction and used to attach IL 6 receptor owing to its excellent biocompatibility and good conductivity. The electrochemical signals of the electrodes during the immunosensor fabrication were performed with electrochemical impedance spectroscopy and cyclic voltammetry techniques. Additionally, the changes formed on ITO electrode surfaces were followed by scanning electron microscopy and atomic force microscopy analyses. Under optimized conditions, the designed biosensor illustrated an ultra-sensitive signal towards IL 6 antigen at a broad concentration range from 0.01 pg/mL to 50 pg/mL. The detection limit and sensitivity were found as 3.2 fg/mL and 0.29 pg?1mLk? cm?2, respectively. Acceptable reproducibility, good storage-stability and excellent selectivity were found for IL 6 determination. Moreover, the proposed biosensor was applied to human serums and the recovery rates were ranged from 99.5 to 100.5 indicating acceptable accuracy. The results illustrated that this immunosensor were suitable for detection of IL 6 in clinical samples. © 2020 Elsevier B.V.
Cilt
222İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ... -
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
Aydın, Muhammet (Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...