Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAydın, Muhammet
dc.date.accessioned2022-05-11T14:48:16Z
dc.date.available2022-05-11T14:48:16Z
dc.date.issued2019
dc.identifier.issn0956-5663
dc.identifier.urihttps://doi.org/10.1016/j.bios.2019.111675
dc.identifier.urihttps://hdl.handle.net/20.500.11776/10619
dc.description.abstractA highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide electrode. This conjugated polymer was synthesized to fabricate this immunosensor for the first time and it offered a good biosensing platform for anti-IL 1? antibody immobilization due to epoxy groups present on the side groups of the polymer. Furthermore, the epoxy-substituted polythiophene polymer coated indium tin oxide electrode was used for the determination of IL 1? antigen for the first time. Electrode fabrication stages were characterized by using electrochemical (electrochemical impedance spectroscopy and cyclic voltammetry) and morphological (scanning electron microscopy and atomic force microscopy) techniques. Under optimum experimental conditions, impedimetric responses of the immunosensor increased with the increasing of IL 1? antigen concentration, and the proposed immunosensor displayed a wide linear detection range from 0.01 pg/mL to 5.5 pg/mL with a detection limit of 3.4 fg/mL. The proposed immunosensor exhibited outstanding performance including excellent reproducibility, good repeatability, high selectivity and long storage stability. With the advantages of simple operation, low-cost fabrication and label-free format, the suggested immunosensor was expected to have potential applications for IL 1? cancer biomarker detection. © 2019 Elsevier B.V.en_US
dc.language.isoengen_US
dc.publisherElsevier Ltden_US
dc.identifier.doi10.1016/j.bios.2019.111675
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectConjugated polymeren_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectEpoxy-substituted polythiopheneen_US
dc.subjectInterleukin 1?en_US
dc.subjectAntigensen_US
dc.subjectAtomic force microscopyen_US
dc.subjectBiomarkersen_US
dc.subjectConjugated polymersen_US
dc.subjectCyclic voltammetryen_US
dc.subjectDiseasesen_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectImmunosensorsen_US
dc.subjectIndium compoundsen_US
dc.subjectScanning electron microscopyen_US
dc.subjectSpectroscopyen_US
dc.subjectTin oxidesen_US
dc.subjectAntibody immobilizationen_US
dc.subjectCancer biomarker detectionsen_US
dc.subjectElectrochemical immunosensorsen_US
dc.subjectElectrode fabricationen_US
dc.subjectExperimental conditionsen_US
dc.subjectIndium tin oxide electrodesen_US
dc.subjectInterleukin-1en_US
dc.subjectLinear detection rangesen_US
dc.subjectElectrochemical electrodesen_US
dc.subjectinterleukin 1alphaen_US
dc.subjectpolyethylene terephthalateen_US
dc.subjectpolymeren_US
dc.subjectpolythiopheneen_US
dc.subjectunclassified drugen_US
dc.subjectepoxy resinen_US
dc.subjectIL1A protein, humanen_US
dc.subjectimmobilized antibodyen_US
dc.subjectindium tin oxideen_US
dc.subjectinterleukin 1alphaen_US
dc.subjectpolymeren_US
dc.subjectpolythiopheneen_US
dc.subjectthiophene derivativeen_US
dc.subjecttin derivativeen_US
dc.subjecttumor markeren_US
dc.subjectArticleen_US
dc.subjectatomic force microscopyen_US
dc.subjectcyclic potentiometryen_US
dc.subjecthumanen_US
dc.subjectimpedance spectroscopyen_US
dc.subjectindium tin oxide electrodeen_US
dc.subjectlimit of detectionen_US
dc.subjectmeasurement repeatabilityen_US
dc.subjectreproducibilityen_US
dc.subjectscanning electron microscopyen_US
dc.subjectserumen_US
dc.subjectchemistryen_US
dc.subjectgenetic proceduresen_US
dc.subjectisolation and purificationen_US
dc.subjectneoplasmen_US
dc.subjectproceduresen_US
dc.subjectAntibodies, Immobilizeden_US
dc.subjectBiomarkers, Tumoren_US
dc.subjectBiosensing Techniquesen_US
dc.subjectDielectric Spectroscopyen_US
dc.subjectEpoxy Resinsen_US
dc.subjectHumansen_US
dc.subjectInterleukin-1alphaen_US
dc.subjectNeoplasmsen_US
dc.subjectPolymersen_US
dc.subjectThiophenesen_US
dc.subjectTin Compoundsen_US
dc.titleA sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymeren_US
dc.typearticleen_US
dc.relation.ispartofBiosensors and Bioelectronicsen_US
dc.departmentRektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezien_US
dc.identifier.volume144en_US
dc.institutionauthorAydın, Muhammet
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55571487900
dc.identifier.scopus2-s2.0-85071935392en_US
dc.identifier.pmid31518789en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster