An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
Özet
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO electrode modification material for anti-PAK 2 antibody immobilization. This molecule had epoxy group, which was reactive to amino groups of antibodies. Anti-PAK 2 antibodies were also used as biomolecules for sensitive interaction for PAK 2 antigen. In the presence of PAK 2 antigens, high impedance signal was observed when the process followed by using Electrochemical Impedance Spectroscopy technique (EIS). Apart from EIS technique, Cyclic Voltammetry (CV), Square Wave Voltammetry (SWV) and Single Frequency Impedance (SFI) techniques were utilized. Microscopic surface characterizations of immunosensor fabrication steps were performed by using Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The immunosensor exhibited good sensitivity and selectivity for PAK 2 antigen detection. A linear calibration curve between EIS response and PAK 2 concentration was obtained in the range of 0.005–0.075 pg/mL with the detection limit of 1.5 fg/mL. It had good repeatability, excellent reproducibility and high stability. Additionally, this immunosensor can be reused by simple application protocol. Furthermore, it had good recovery for PAK 2 antigen detection in human serum samples. The good recovery illustrated that the developed immunosensor was a promising tool for PAK 2 detection in practical applications. © 2019 Elsevier B.V.
Cilt
1062İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2020)A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ... -
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
Aydın, Elif Burcu (Elsevier B.V., 2020)A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ... -
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...