Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
Özet
In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were attached on the 3-phosphonopropionic acid (PHP) modified FTO surface covalently. Electrochemical (electrochemical impedance spectroscopy and cyclic voltammetry) and morphological (scanning electron microscopy and atomic force microscopy) characterizations were performed to monitor the successful fabrication of immunoelectrodes. After incubation of anti-IL-1? antibody immobilized FTO electrodes in IL-1? antigen solutions, increases were seen in impedimetric responses. IL-1? antigen was determined in a linear detection range from 0.02 to 2 pg/mL by EIS. The detection limit of the suggested immunosensor was 6 fg/mL. The applicability of the designed biosensor was tested by using human serum and saliva samples and acceptable results were obtained. In addition, high sensitivity, good specificity, low detection limit made the proposed immunosensor a potential technique for IL-1? antigen determination in routine clinical analysis. © 2020 Elsevier B.V.
Cilt
138İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
Fabrication of Electrochemical Immunosensor for Detection of Interleukin 8 Biomarker via Layer-by-layer Self-assembly Process on Cost-effective Fluorine Tin Oxide Electrode
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (John Wiley and Sons Inc, 2021)A highly sensitive impedimetric immunosensor for the determination of interleukin 8 (IL 8) cancer biomarker was fabricated via simple fabrication process. A silane agent with isocyanate groups, 3-(triethoxysilyl)propyl ... -
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
Aydın, Muhammet (Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...