Konu "Cyclic voltammetry" için Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezi Koleksiyonu listeleme
Toplam kayıt 13, listelenen: 1-13
-
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ... -
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ... -
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ... -
A label-free and sensitive impedimetric immunosensor for TNF ? biomarker detection based on epoxysilane-modified disposable ITO-PET electrode
(Taylor and Francis Ltd., 2020)The present study constructed a simple and cost-effective electrochemical immunosensor based on 3-glycidoxypropyltriethoxysilane (GPTES) monolayer coated indium tin oxide-polyethylene terephthalate (ITO-PET) electrode for ... -
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
(Elsevier B.V., 2021)An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ... -
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ... -
Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
(Elsevier B.V., 2021)In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were ... -
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ... -
An ultrasensitive immunosensor based on tri-armed star poly(glycidyl methacrylate) polymer-coated ITO-PET electrode for detection of neuron-specific enolase in human serum
(Taylor and Francis Ltd., 2020)In the present study, an ultrasensitive and simple impedimetric biosensor was fabricated for the determination of neuron-specific enolase (NSE) cancer biomarker. Anti-NSE antibody was covalently immobilised on the indium ...