Konu "Electrochemical impedance spectroscopy" için PubMed İndeksli Yayın Koleksiyonu listeleme
Toplam kayıt 26, listelenen: 1-20
-
Analysis of Tau-441 protein in clinical samples using rGO/AuNP nanocomposite-supported disposable impedimetric neuro-biosensing platform: Towards Alzheimer's disease detection
(Elsevier B.V., 2020)Changes in isoforms of Tau protein, which are critical for microtubule functioning, are accepted as being responsible for diseases characterized by dementia, in particular Alzheimer's disease (AD). In this comprehensive ... -
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
Development of an impedimetric aflatoxin M1 biosensor based on a DNA probe and gold nanoparticles
(Elsevier Advanced Technology, 2011)The present work describes the construction and application of a new DNA biosensor for detection of aflatoxin M1. In order to immobilize a thiol-modified single stranded DNA (ss-HSDNA) probe that specifically bound aflatoxin ... -
A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1 beta in human serum and saliva
(Elsevier Science Bv, 2018)In this study, we constructed a new and sensitive ITO based electrochemical immunosensor for detection of interleukin 1 beta(IL-1 beta), a cancer biomarker found in serum and saliva. 6-phosphonohexanoic acid (PHA) was used ... -
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ... -
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ... -
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
(Elsevier Advanced Technology, 2018)A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ... -
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ... -
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ... -
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ... -
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ... -
An impedimetric vascular endothelial growth factor biosensor-based PAMAM/cysteamine-modified gold electrode for monitoring of tumor growth
(Academic Press Inc Elsevier Science, 2012)In the present work, we have developed a new biosensor based on fourth-generation (G4) PAMAM dendrimers for the analysis of vascular endothelial growth factor (VEGF). First, the PAMAM dendrimers were covalently attached ... -
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
(Elsevier B.V., 2020)A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ... -
A nano-composite based regenerative neuro biosensor sensitive to Parkinsonism-associated protein DJ-1/Park7 in cerebrospinal fluid and saliva
(Elsevier B.V., 2021)In this study, we developed an electrochemical-based single-use neurobiosensor based on multiwalled carbon nanotube (MWCNT)-gold nanoparticle (AuNP) nanocomposite doped, 11-amino-1-undecanethiol (11-AUT)-modified polyethylene ... -
A new impedimetric biosensor utilizing VEGF receptor-1 (Flt-1): Early diagnosis of vascular endothelial growth factor in breast cancer
(Elsevier Advanced Technology, 2011)A new impedimetric biosensor, based on the use of vascular endothelial growth factor receptor-1 (VEGF-R1), was developed for the determination of vascular endothelial growth factor (VEGF). VEGF-R1 was immobilized through ... -
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
(Elsevier B.V., 2021)An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ... -
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker
(Elsevier, 2014)A specific and sensitive biosensor was developed successfully for quantitative detection of human epidermal growth factor receptor by electrochemical impedance spectroscopy. Anti-human epidermal growth factor receptor ...