Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
(Wiley-VCH Verlag, 2021)
Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ...
Fabrication of Electrochemical Immunosensor for Detection of Interleukin 8 Biomarker via Layer-by-layer Self-assembly Process on Cost-effective Fluorine Tin Oxide Electrode
(John Wiley and Sons Inc, 2021)
A highly sensitive impedimetric immunosensor for the determination of interleukin 8 (IL 8) cancer biomarker was fabricated via simple fabrication process. A silane agent with isocyanate groups, 3-(triethoxysilyl)propyl ...
Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
(Elsevier B.V., 2021)
In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were ...
Ultrasensitive and Selective Impedimetric Determination of Prostate Specific Membrane Antigen Based on Di-Succinimide Functionalized Polythiophene Covered Cost-Effective Indium Tin Oxide
(John Wiley and Sons Inc, 2021)
A new and ultrasensitive impedimetric biosensor fabricated by using conjugated di-succinimide substituted polythiophene (P(ThidiSuc)) polymer modified indium tin oxide electrode is developed for the first time to detect ...
The effects of polymorphisms in the CX3CR1 gene on the development of canine hip dysplasia
(TUBITAK, 2022)
Hip dysplasia, caused by both environmental and genetic components, is a common disorder characterized by hip instability in humans and dogs. Unfortunately, the genetic mechanisms that cause the disease in both have not ...
Detection of Kallikrein-Related Peptidase 4 with a Label-free Electrochemical Impedance Biosensor Based on a Zinc(II) Phthalocyanine Tetracarboxylic Acid-Functionalized Disposable Indium Tin Oxide Electrode
(Amer Chemical Soc, 2021)
A new impedimetric biosensing system based on kallikrein-related peptidase 4 (KLK 4) antigen-specific antibodies and a zinc(II) phthalocyanine tetracarboxylic acid (Zn-PcTCa) matrix material was developed for the first ...
Biosensors and the evaluation of food contaminant biosensors in terms of their performance criteria
(Taylor and Francis Ltd., 2020)
Biosensor technology has been extensively investigated for determination of several analytes in clinical diagnosis, food analysis and environmental monitoring. A biosensor includes three parts; a transducer, a bioreceptor ...
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
(Elsevier B.V., 2020)
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ...
An ultrasensitive immunosensor based on tri-armed star poly(glycidyl methacrylate) polymer-coated ITO-PET electrode for detection of neuron-specific enolase in human serum
(Taylor and Francis Ltd., 2020)
In the present study, an ultrasensitive and simple impedimetric biosensor was fabricated for the determination of neuron-specific enolase (NSE) cancer biomarker. Anti-NSE antibody was covalently immobilised on the indium ...
A Label-free Electrochemical Immunosensor for Highly Sensitive Detection of TNF alpha, Based on Star Polymer-modified disposable ITO Electrode
(Bentham Science Publ Ltd, 2021)
Background: Biomarkers are very important disease-related biomolecules which should be analyzed sensitive and selective in related physiological fluids or tissues. Tumor necrosis factor-alpha is a type of cytokine which ...