Yazar "Sezgintürk, Mustafa Kemal" için PubMed İndeksli Yayın Koleksiyonu listeleme
-
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3
Canbaz, Mehmet Çetin; Şimşek, Çiğdem Sayikli; Sezgintürk, Mustafa Kemal (Elsevier Science Bv, 2014)We have developed a new immunological biosensor for ultrasensitive quantification of human epidermal growth factor receptor-3(HER-3). In order to construct the biosensor, the gold electrode surface was layered with, ... -
Electrochemical biosensors for hormone analyses
Bahadır, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Advanced Technology, 2015)Electrochemical biosensors have a unique place in determination of hormones due to simplicity, sensitivity, portability and ease of operation. Unlike chromatographic techniques, electrochemical techniques used do not require ... -
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier Advanced Technology, 2018)In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ... -
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Ltd, 2019)A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ... -
Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Wiley-VCH Verlag, 2021)Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
Yılmaz, Nergiz; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection
Canbaz, Mehmet Çetin; Sezgintürk, Mustafa Kemal (Academic Press Inc Elsevier Science, 2014)Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane ... -
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ... -
Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70
Özcan, Burcu; Sezgintürk, Mustafa Kemal (Elsevier Science Bv, 2016)In this study, it is aimed to design a label free immunosensor for determination of HSP70 (heat shock protein 70). Glassy carbon electrode was used as a working electrode. Graphene oxide was covered on the working electrode ... -
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Advanced Technology, 2018)A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ... -
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Wiley-VCH Verlag, 2019)In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ... -
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier Advanced Technology, 2017)A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ... -
Immobilization of anti-aflatoxin B1 antibody by UV polymerization of aniline and aflatoxin B1 detection via electrochemical impedance spectroscopy
Dinçkaya, Erhan; Kinik, Ozer; Sezgintürk, Mustafa Kemal; Altuğ, Çağrı; Akkoca, Aylin (Informa Healthcare, 2012)In the study, we investigated the practicality of the UV polymerization of aniline for anti-aflatoxin B1 antibody immobilization, and utilization of the resulting biosensor in the impedimetric determination of aflatoxin ... -
Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Amer Chemical Soc, 2022)A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis ... -
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Academic Press Inc Elsevier Science, 2018)In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ... -
An impedimetric vascular endothelial growth factor biosensor-based PAMAM/cysteamine-modified gold electrode for monitoring of tumor growth
Sezgintürk, Mustafa Kemal; Uygun, Zihni Onur (Academic Press Inc Elsevier Science, 2012)In the present work, we have developed a new biosensor based on fourth-generation (G4) PAMAM dendrimers for the analysis of vascular endothelial growth factor (VEGF). First, the PAMAM dendrimers were covalently attached ... -
Introducing a new method for evaluation of the interaction between an antigen and an antibody: Single frequency impedance analysis for biosensing systems
Özcan, Burcu; Demirbakan, Burçak; Yeşiller, Gülden; Sezgintürk, Mustafa Kemal (Elsevier Science Bv, 2014)This paper illustrates the application of an antibody, anti-parathyroid hormone (anti-PTH), as a bioreceptor in a biosensor system for the first time, and demonstrates how this biosensor can be used in parathyroid hormone ... -
A label-free electrochemical biosensor for direct detection of RACK 1 by using disposable, low-cost and reproducible ITO based electrode
Törer, Hakan; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Science Bv, 2018)In this study we designed an ultrasensitive electrochemical immunosensor for RACK 1 detection using 11-cyanoundecyltrimethoxysilane (11-CUTMS) as a immobilization matrix to immobilize biorecognition element. The used silane ... -
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2020)A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ...