Ara
Toplam kayıt 69, listelenen: 31-40
An ITO Based Disposable Biosensor for Ultrasensitive Analysis of Retinol Binding Protein
(Wiley-V C H Verlag Gmbh, 2014)
A highly sensitive electrochemical biosensor based on anti-RBP biorecognition capable to analyze concentrations of retinol binding protein (RBP) was developed. The construction of the biosensor interfaces was carefully ...
Sulfite Determination by an Inhibitor Biosensor-based Mushroom (Agaricus Bisporus) Tissue Homogenate
(Informa Healthcare, 2012)
The aim of the study presented here is to develop a biosensor based on mushroom (Agaricus bisporus) tissue homogenate for sensitive and economical determination of sulfite in foods. The working principle of the biosensor ...
Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70
(Elsevier Science Bv, 2016)
In this study, it is aimed to design a label free immunosensor for determination of HSP70 (heat shock protein 70). Glassy carbon electrode was used as a working electrode. Graphene oxide was covered on the working electrode ...
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)
An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ...
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)
This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ...
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)
A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ...
Highly selective and sensitive sandwich immunosensor platform modified with MUA-capped GNPs for detection of spike Receptor Binding Domain protein: A precious marker of COVID-19 infection
(Elsevier B.V., 2021)
A label-free electrochemical biosensing system as a suitable analysis technique for COVID 19 specific spike receptor-binding domain protein (RBD) was developed with an aim to facilitate the diagnosis of coronavirus. A novel ...
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
(Elsevier B.V., 2021)
An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ...
Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
(Wiley-VCH Verlag, 2021)
Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ...
Fabrication of Electrochemical Immunosensor for Detection of Interleukin 8 Biomarker via Layer-by-layer Self-assembly Process on Cost-effective Fluorine Tin Oxide Electrode
(John Wiley and Sons Inc, 2021)
A highly sensitive impedimetric immunosensor for the determination of interleukin 8 (IL 8) cancer biomarker was fabricated via simple fabrication process. A silane agent with isocyanate groups, 3-(triethoxysilyl)propyl ...