Ara
Toplam kayıt 60, listelenen: 41-50
A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer
(Elsevier Science Bv, 2017)
A novel, sensitive, disposable indium tin oxide (ITO)-based electrochemical immunosensor was developed firstly for simple, rapid determination of Sex-determining region Y-box 2 (SOX2). SOX2 is a cancer biomarker and used ...
The development of an ultra-sensitive electrochemical immunosensor using a PPyr-NHS functionalized disposable ITO sheet for the detection of interleukin 6 in real human serums
(Royal Soc Chemistry, 2020)
A label-free impedimetric immunosensor based on a conjugated poly(pyrroleN-hydroxy succinimide) (PPyr-NHS) polymer covered disposable indium tin oxide electrode (ITO) was fabricated for the ultrasensitive determination of ...
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ...
A label-free and sensitive impedimetric immunosensor for TNF ? biomarker detection based on epoxysilane-modified disposable ITO-PET electrode
(Taylor and Francis Ltd., 2020)
The present study constructed a simple and cost-effective electrochemical immunosensor based on 3-glycidoxypropyltriethoxysilane (GPTES) monolayer coated indium tin oxide-polyethylene terephthalate (ITO-PET) electrode for ...
Alloreactive memory B cell detection by flow cytometric cross match using polyclonally activated memory B cell culture supernatants
(Elsevier, 2022)
In addition to alloantibodies, alloreactive memory B cell (mBC) evaluation has a potential for immunological risk assessment during transplantation processes. For the alloreactive mBCs evaluation currently, direct Flow ...
Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite
(Amer Chemical Soc, 2022)
A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis ...
Label-free and reagent-less electrochemical detection of nucleocapsid protein of SARS-CoV-2: an ultrasensitive and disposable biosensor
(Royal Soc Chemistry, 2022)
A novel selective and ultrasensitive sandwich biosensor was developed for the detection of nucleocapsid biomarkers of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The biosensor fabrication strategy was ...
Investigation of alpha globin gene mutations by complementary methods in Antalya
(Yuzuncu Yil Universitesi Tip Fakultesi, 2021)
Alpha (?) thalassemia is one of the hemoglobinopaties that is inherited by autosomal recessive mode. It is caused by mutations on alpha-1 and alpha-2 globin genes. Deletional type mutations of globin genes have commonly ...
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...