Biosensors and the evaluation of food contaminant biosensors in terms of their performance criteria
dc.authorscopusid | 57194273220 | |
dc.authorscopusid | 55571487900 | |
dc.authorscopusid | 6506764918 | |
dc.contributor.author | Burcu Aydın, E. | |
dc.contributor.author | Aydın, M. | |
dc.contributor.author | Kemal Sezgintürk, M. | |
dc.date.accessioned | 2022-05-11T14:07:24Z | |
dc.date.available | 2022-05-11T14:07:24Z | |
dc.date.issued | 2020 | |
dc.department | Rektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezi | |
dc.description.abstract | Biosensor technology has been extensively investigated for determination of several analytes in clinical diagnosis, food analysis and environmental monitoring. A biosensor includes three parts; a transducer, a bioreceptor (biorecognition element) and a signal processing system. Biorecognition elements are important components of a biosensor because they recognise the target analytes of interest. To obtain a sensitive and a reproducible biosensor, nanomaterials are used as modification elements of transducer. They represent important promise as biorecognition element immobilisation platforms for the biosensor fabrication. This mini review summarises the biosensor’ features, the factors affect its performance and nanomaterials, which are used as modification elements in food analysis area. After a brief description of the biosensors and nanomaterials, the developed biosensors in literature were investigated by means of tables. Linear ranges, LODs, reproducibilities, stabilities of developed biosensors are compared. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group. | |
dc.identifier.doi | 10.1080/03067319.2019.1672675 | |
dc.identifier.endpage | 622 | |
dc.identifier.issn | 0306-7319 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.scopus | 2-s2.0-85074054433 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 602 | |
dc.identifier.uri | https://doi.org/10.1080/03067319.2019.1672675 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11776/5093 | |
dc.identifier.volume | 100 | |
dc.identifier.wos | WOS:000489364800001 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.institutionauthor | Burcu Aydın, E. | |
dc.language.iso | en | |
dc.publisher | Taylor and Francis Ltd. | |
dc.relation.ispartof | International Journal of Environmental Analytical Chemistry | |
dc.relation.publicationcategory | Diğer | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | biorecognition elements | |
dc.subject | Biosensors | |
dc.subject | immunosensors | |
dc.subject | nanomaterials | |
dc.subject | performance criteria | |
dc.subject | Biosensors | |
dc.subject | Diagnosis | |
dc.subject | Environmental technology | |
dc.subject | Nanostructured materials | |
dc.subject | Signal processing | |
dc.subject | Transducers | |
dc.subject | Biorecognition elements | |
dc.subject | Biosensor fabrication | |
dc.subject | Clinical diagnosis | |
dc.subject | Environmental Monitoring | |
dc.subject | Food contaminants | |
dc.subject | Performance criterion | |
dc.subject | Reproducibilities | |
dc.subject | Signal processing systems | |
dc.subject | Immunosensors | |
dc.title | Biosensors and the evaluation of food contaminant biosensors in terms of their performance criteria | |
dc.type | Review Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 5093.pdf
- Boyut:
- 1.86 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text