Measurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R))

dc.authorscopusid55316940600
dc.authorscopusid57202440441
dc.authorscopusid56154634600
dc.authorscopusid6603924496
dc.authorscopusid7006243697
dc.authorwosidKilic, Servet/ABA-3409-2020
dc.contributor.authorKulualp, Kadri
dc.contributor.authorYurdakul, İbrahim
dc.contributor.authorErol, Hanifi
dc.contributor.authorAtalan, Gültekin
dc.contributor.authorKılıç, Servet
dc.date.accessioned2022-05-11T14:42:13Z
dc.date.available2022-05-11T14:42:13Z
dc.date.issued2018
dc.departmentFakülteler, Veteriner Fakültesi, Klinik Bilimler Bölümü, Cerrahi Ana Bilim Dalı
dc.description.abstractThe current study was undertaken to establish reference values of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R)). Twenty-eight dogs (14 male and 14 female, aged 9 months-9 years, 56 eyes) were used in this study. All animals were healthy and showed no abnormalities in ophthalmic examinations, which consisted of the Schirmer tear test, slit lamp bio-microscopy, and fluorescein staining. The animals were restrained manually without using systemic anesthetics or tranquilizers. IOP was measured in both eyes with a TonoVet (R) and a Tono-Pen Vet (R). In normal dogs, the mean IOP values for all eyes were 17.63 +/- 3.34 mmHg according to the TonoVet (R) and 14.95 +/- 2.92 mmHg according to the Tono-Pen Vet (R). There was no effect of sex, age, or eye side (right vs. left) on the results obtained with either the TonoVet (R) or the Tono-Pen Vet (R). The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. The reference data obtained in the present study may assist in diagnostic testing for ophthalmic diseases in Turkish Shepherd Dogs and may promote further studies in this area.
dc.identifier.doi10.21521/mw.6024
dc.identifier.endpage573
dc.identifier.issn0025-8628
dc.identifier.issue9en_US
dc.identifier.scopus2-s2.0-85054822766
dc.identifier.scopusqualityQ3
dc.identifier.startpage568
dc.identifier.urihttps://doi.org/10.21521/mw.6024
dc.identifier.urihttps://hdl.handle.net/20.500.11776/9289
dc.identifier.volume74
dc.identifier.wosWOS:000442755200003
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorKılıç, Servet
dc.language.isoen
dc.publisherPolish Soc Veterinary Sciences Editorial Office
dc.relation.ispartofMedycyna Weterynaryjna-Veterinary Medicine-Science and Practice
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectapplanation tonometry
dc.subjectrebound tonometry
dc.subjectdog
dc.subjecteye
dc.subjectintraocular pressure
dc.subjectCentral Corneal Thickness
dc.subjectOphthalmic Diagnostic-Tests
dc.subjectPupil Diameter
dc.subjectKangal Dogs
dc.subjectHealthy Dogs
dc.subjectMorphological-Characteristics
dc.subjectReference Values
dc.subjectTear Production
dc.subjectCanine Eyes
dc.subjectHydrochloride
dc.titleMeasurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R))
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
9289.pdf
Boyut:
602.65 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text