Treatment of mixed astigmatism: early clinical outcomes with WaveLight and Technolas excimer lasers

dc.authorid0000-0001-8990-9365
dc.authorid0000-0002-4018-9798
dc.authorscopusid57053382500
dc.authorscopusid34869701000
dc.authorscopusid55960343600
dc.authorscopusid6603443273
dc.authorscopusid8073283000
dc.authorwosidKilavuzoglu, Ayse Ebru/I-1268-2015
dc.authorwosidCelebi, Ali Riza Cenk/I-3906-2013
dc.authorwosidCosar, Cemile Banu/D-6634-2016
dc.contributor.authorKilavuzoglu, Ayse Ebru
dc.contributor.authorGönen, Tansu
dc.contributor.authorÇelebi, Ali Riza Cenk
dc.contributor.authorCoşar Yurteri, Cemile Banu
dc.contributor.authorŞener, Asım Bozkurt
dc.date.accessioned2022-05-11T14:35:47Z
dc.date.available2022-05-11T14:35:47Z
dc.date.issued2016
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.description.abstractBackground/aim: We aimed to compare the results of WaveLight Allegretto Wave Eye-Q 400 Hz and Technolas 217z100 excimer lasers in the treatment of mixed astigmatism. Materials and methods: Forty-nine patients who underwent laser in situ keratomileusis for mixed astigmatism were included in this retrospective study. Twenty-eight eyes of 21 patients were treated with WaveLight and 46 eyes of 28 patients were treated with the Technolas excimer laser. The patients' visual acuities and refractive values were evaluated on postoperative day 1 and at 1 and 3 months. Results: In the WaveLight and Technolas groups, cylindrical refractive errors at month 3 were -0.92 +/- 0.28 D and -0.88 +/- 0.46 D, respectively. Spherical equivalent values for the groups at month 3 were -0.38 perpendicular to 0.73 D and -0.33 perpendicular to 0.20 D, respectively. There was no significant difference in postoperative uncorrected distance visual acuity at month 3 between the two groups (P = 0.671). At postoperative month 3, 70% of patients treated with WaveLight and 100% of patients treated with Technolas had an uncorrected distance visual acuity of 20/25 or better (P = 0.211). Conclusion: There were no significant differences in refraction and visual acuity between the WaveLight and Technolas groups during a 3-month follow-up period after laser in situ keratomileusis for mixed astigmatism.
dc.identifier.doi10.3906/sag-1504-35
dc.identifier.endpage672
dc.identifier.issn1300-0144
dc.identifier.issn1303-6165
dc.identifier.issue3en_US
dc.identifier.pmid27513239
dc.identifier.scopus2-s2.0-84964047288
dc.identifier.scopusqualityQ3
dc.identifier.startpage664
dc.identifier.urihttps://doi.org/10.3906/sag-1504-35
dc.identifier.urihttps://hdl.handle.net/20.500.11776/8215
dc.identifier.volume46
dc.identifier.wosWOS:000374327500012
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorGönen, Tansu
dc.language.isoen
dc.publisherTubitak Scientific & Technical Research Council Turkey
dc.relation.ispartofTurkish Journal of Medical Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectExcimer laser
dc.subjectlaser in situ keratomileusis
dc.subjectmixed astigmatism
dc.subjectIn-Situ Keratomileusis
dc.subjectHyperopic Astigmatism
dc.subjectEye-Q
dc.subjectLasik
dc.subjectKeratotomy
dc.titleTreatment of mixed astigmatism: early clinical outcomes with WaveLight and Technolas excimer lasers
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8215.pdf
Boyut:
312.44 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text