A review on impedimetric biosensors
dc.authorscopusid | 56465916100 | |
dc.authorscopusid | 6506764918 | |
dc.authorwosid | Sezgintürk, Mustafa Kemal/AAY-1439-2021 | |
dc.contributor.author | Bahadır, Elif Burcu | |
dc.contributor.author | Sezgintürk, Mustafa Kemal | |
dc.date.accessioned | 2022-05-11T14:12:19Z | |
dc.date.available | 2022-05-11T14:12:19Z | |
dc.date.issued | 2016 | |
dc.department | Rektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezi | |
dc.department | Fakülteler, Fen Edebiyat Fakültesi, Kimya Bölümü | |
dc.description.abstract | Electrochemical impedance spectroscopy (EIS) is a sensitive technique for the analysis of the interfacial properties related to biorecognition events such as reactions catalyzed by enzymes, biomolecular recognition events of specific binding proteins, lectins, receptors, nucleic acids, whole cells, antibodies or antibody-related substances, occurring at the modified surface. Many studies on impedimetric biosensors are focused on immunosensors and aptasensors. In impedimetric immunosensors, antibodies and antigens are bound each other and thus immunocomplex is formed and the electrode is coated with a blocking layer. As a result of that electron transfer resistance increases. In impedimetric aptasensors, impedance changes following the binding of target sequences, conformational changes, or DNA damages. Impedimetric biosensors allow direct detection of biomolecular recognition events without using enzyme labels. In this paper, impedimetric biosensors are reviewed and the most interesting ones are discussed. | |
dc.identifier.doi | 10.3109/21691401.2014.942456 | |
dc.identifier.endpage | 262 | |
dc.identifier.issn | 2169-1401 | |
dc.identifier.issn | 2169-141X | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 25211230 | |
dc.identifier.scopus | 2-s2.0-84971665294 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 248 | |
dc.identifier.uri | https://doi.org/10.3109/21691401.2014.942456 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11776/5499 | |
dc.identifier.volume | 44 | |
dc.identifier.wos | WOS:000368022400033 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Bahadır, Elif Burcu | |
dc.institutionauthor | Sezgintürk, Mustafa Kemal | |
dc.language.iso | en | |
dc.publisher | Taylor & Francis Ltd | |
dc.relation.ispartof | Artificial Cells Nanomedicine and Biotechnology | |
dc.relation.publicationcategory | Diğer | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | biosensor | |
dc.subject | electrochemical impedance spectroscopy | |
dc.subject | impedance-based biosensor | |
dc.subject | Label-Free Detection | |
dc.subject | Gold Nanoparticles | |
dc.subject | Sensitive Detection | |
dc.subject | Electrochemical Detection | |
dc.subject | Impedance Spectroscopy | |
dc.subject | Signal Amplification | |
dc.subject | Ultrasensitive Detection | |
dc.subject | Disposable Immunosensor | |
dc.subject | Salmonella-Typhimurium | |
dc.subject | Dna Hybridization | |
dc.title | A review on impedimetric biosensors | |
dc.type | Review Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 5499.pdf
- Boyut:
- 316.5 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text