A review on impedimetric biosensors

dc.authorscopusid56465916100
dc.authorscopusid6506764918
dc.authorwosidSezgintürk, Mustafa Kemal/AAY-1439-2021
dc.contributor.authorBahadır, Elif Burcu
dc.contributor.authorSezgintürk, Mustafa Kemal
dc.date.accessioned2022-05-11T14:12:19Z
dc.date.available2022-05-11T14:12:19Z
dc.date.issued2016
dc.departmentRektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezi
dc.departmentFakülteler, Fen Edebiyat Fakültesi, Kimya Bölümü
dc.description.abstractElectrochemical impedance spectroscopy (EIS) is a sensitive technique for the analysis of the interfacial properties related to biorecognition events such as reactions catalyzed by enzymes, biomolecular recognition events of specific binding proteins, lectins, receptors, nucleic acids, whole cells, antibodies or antibody-related substances, occurring at the modified surface. Many studies on impedimetric biosensors are focused on immunosensors and aptasensors. In impedimetric immunosensors, antibodies and antigens are bound each other and thus immunocomplex is formed and the electrode is coated with a blocking layer. As a result of that electron transfer resistance increases. In impedimetric aptasensors, impedance changes following the binding of target sequences, conformational changes, or DNA damages. Impedimetric biosensors allow direct detection of biomolecular recognition events without using enzyme labels. In this paper, impedimetric biosensors are reviewed and the most interesting ones are discussed.
dc.identifier.doi10.3109/21691401.2014.942456
dc.identifier.endpage262
dc.identifier.issn2169-1401
dc.identifier.issn2169-141X
dc.identifier.issue1en_US
dc.identifier.pmid25211230
dc.identifier.scopus2-s2.0-84971665294
dc.identifier.scopusqualityQ1
dc.identifier.startpage248
dc.identifier.urihttps://doi.org/10.3109/21691401.2014.942456
dc.identifier.urihttps://hdl.handle.net/20.500.11776/5499
dc.identifier.volume44
dc.identifier.wosWOS:000368022400033
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorBahadır, Elif Burcu
dc.institutionauthorSezgintürk, Mustafa Kemal
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofArtificial Cells Nanomedicine and Biotechnology
dc.relation.publicationcategoryDiğeren_US
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectbiosensor
dc.subjectelectrochemical impedance spectroscopy
dc.subjectimpedance-based biosensor
dc.subjectLabel-Free Detection
dc.subjectGold Nanoparticles
dc.subjectSensitive Detection
dc.subjectElectrochemical Detection
dc.subjectImpedance Spectroscopy
dc.subjectSignal Amplification
dc.subjectUltrasensitive Detection
dc.subjectDisposable Immunosensor
dc.subjectSalmonella-Typhimurium
dc.subjectDna Hybridization
dc.titleA review on impedimetric biosensors
dc.typeReview Article

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
5499.pdf
Boyut:
316.5 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text