A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode

Yükleniyor...
Küçük Resim

Tarih

2020

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier B.V.

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was used as an immobilization matrix for construction of RACK 1 immunosensor. This polymer had a great number of carboxyl groups on its end site and these carboxyl ends provided anchoring points to the anti-RACK 1 antibodies. Anti-RACK 1 antibodies were covalently attached on the ITO electrode and recognized the RACK 1 antigens. Electrochemical characterizations were made by employing electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Additionally, single frequency impedance method (SFI) was applied to follow the specific biointeraction between antibody and antigen. As a result of specific biointeraction, the designed immunosensor exhibited a wide linear detection range between 0.01 pg/mL and 2 pg/mL RACK 1 with a detection limit of 3.1 fg/mL. Scanning electron microscopy and atomic force microscopy analyses were employed for electrode surface morphology investigation. The designed RACK 1 biosensor had good repeatability (5.73 %, RSD), excellent reproducibility (2.5 %, RSD), long storage-stability and reusable property. In addition, the fabricated RACK 1 biosensor was applied to determine RACK 1 concentration in human serums and the recovery was ranging from 98.79%–100.22%. This work illustrated a new tool to construct a sensitive and low-cost disposable biosensor for applications in clinical monitoring. © 2020 Elsevier B.V.

Açıklama

Anahtar Kelimeler

Cancer biomarker, Conjugated polymer, Electrochemical biosensor, Electrochemical impedance spectroscopy, Receptor for activated C kinase 1, immobilized antibody, indium tin oxide, poly(3 thiophene acetic acid), polyethylene terephthalate, polymer, protein antibody, receptor for activated C kinase 1, unclassified drug, indium tin oxide, polymer, tin derivative, tumor marker, antigen detection, Article, atomic force microscopy, conjugation, controlled study, cyclic voltammetry, electrochemical detection, human, immobilization, impedance spectroscopy, limit of detection, limit of quantitation, priority journal, scanning electron microscopy, serum, electrochemical analysis, electrode, genetic procedures, immunoassay, neoplasm, reproducibility, Antibodies, Immobilized, Biomarkers, Tumor, Biosensing Techniques, Electrochemical Techniques, Electrodes, Humans, Immunoassay, Limit of Detection, Neoplasms, Polymers, Reproducibility of Results, Tin Compounds

Kaynak

Journal of Pharmaceutical and Biomedical Analysis

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

190

Sayı

Künye