A novel immunosensor based on fullerene C60 for electrochemical analysis of heat shock protein 70
dc.authorscopusid | 56106371600 | |
dc.authorscopusid | 6506764918 | |
dc.authorwosid | Sezgintürk, Mustafa Kemal/AAY-1439-2021 | |
dc.contributor.author | Demirbakan, Burcak | |
dc.contributor.author | Sezgintürk, Mustafa Kemal | |
dc.date.accessioned | 2022-05-11T14:30:53Z | |
dc.date.available | 2022-05-11T14:30:53Z | |
dc.date.issued | 2016 | |
dc.department | Fakülteler, Fen Edebiyat Fakültesi, Kimya Bölümü | |
dc.description.abstract | This study illustrates the development of the biosensor for the determination of the heat shock protein 70 (HSP70). For this purpose, firstly the biosensor based on the glassy carbon electrode (GCE) was modified with fullerene C-60. The anti-HSP70 was bound on fullerene C-60 layer by using the EDC/NHS couple. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods were applied to characterize the immobilization of anti-HSP70 process and to determine the HSP70. In order to clarify the binding characterization of HSP70 and anti-HSP70, a single frequency impedance method was utilized, whereas the scanning electron microscopy was used to identify the surface morphology and Kramers-Kronig transform was implemented on impedance data. The biosensor exhibited good repeatability and reproducibility. The linear detection range of the developed biosensor was of 0.8 pg-12.8 pg/mL. Real human blood serum samples were analyzed by the biosensor and the results were also validated by using a reference method based on ELISA. (C) 2016 Elsevier B.V. All rights reserved. | |
dc.description.sponsorship | TUBITAK (The Scientific and Technological Research Council of Turkey)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [113 Z 678] | |
dc.description.sponsorship | This work was funded by TUBITAK (The Scientific and Technological Research Council of Turkey, Project number: 113 Z 678) whose assistance is greatly acknowledged. | |
dc.identifier.doi | 10.1016/j.jelechem.2016.11.020 | |
dc.identifier.endpage | 207 | |
dc.identifier.issn | 1572-6657 | |
dc.identifier.issn | 1873-2569 | |
dc.identifier.scopus | 2-s2.0-85002373823 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 201 | |
dc.identifier.uri | https://doi.org/10.1016/j.jelechem.2016.11.020 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11776/7215 | |
dc.identifier.volume | 783 | |
dc.identifier.wos | WOS:000390627500028 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.institutionauthor | Demirbakan, Burcak | |
dc.institutionauthor | Sezgintürk, Mustafa Kemal | |
dc.language.iso | en | |
dc.publisher | Elsevier Science Sa | |
dc.relation.ispartof | Journal of Electroanalytical Chemistry | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | Fullerene C-60 | |
dc.subject | Heat shock protein (HSP70) | |
dc.subject | Biosensor | |
dc.subject | Electrochemical impedance spectroscopy (EIS) | |
dc.subject | Cancer biomarkers | |
dc.subject | Heat-Shock Proteins | |
dc.subject | Hsp70 | |
dc.subject | C-60 | |
dc.subject | Inhibition | |
dc.subject | Electrodes | |
dc.subject | Biosensors | |
dc.subject | Biomarker | |
dc.subject | Systems | |
dc.subject | Death | |
dc.subject | Cells | |
dc.title | A novel immunosensor based on fullerene C60 for electrochemical analysis of heat shock protein 70 | |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 7215.pdf
- Boyut:
- 1.26 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text