Ara
Toplam kayıt 8, listelenen: 1-8
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ...
Ultrasensitive electrochemical detection of cancer associated biomarker HER3 based on anti-HER3 biosensor
(Elsevier, 2014)
The development of a new impedimetric biosensor for the detection of HER3, based on self-assembled monolayers (SAMs) of 4-aminothiophenol on gold electrodes, is reported. Anti-HER3 was used as a biorecognition element for ...
An impedimetric vascular endothelial growth factor biosensor-based PAMAM/cysteamine-modified gold electrode for monitoring of tumor growth
(Academic Press Inc Elsevier Science, 2012)
In the present work, we have developed a new biosensor based on fourth-generation (G4) PAMAM dendrimers for the analysis of vascular endothelial growth factor (VEGF). First, the PAMAM dendrimers were covalently attached ...
Development of an impedimetric aflatoxin M1 biosensor based on a DNA probe and gold nanoparticles
(Elsevier Advanced Technology, 2011)
The present work describes the construction and application of a new DNA biosensor for detection of aflatoxin M1. In order to immobilize a thiol-modified single stranded DNA (ss-HSDNA) probe that specifically bound aflatoxin ...
A novel, ultra sensible biosensor built by layer-by-layer covalent attachment of a receptor for diagnosis of tumor growth
(Elsevier, 2011)
In the presented research, a novel, ultra sensitive biosensor for the impedimetric detection of vascular endothelial growth factor (VEGF) is introduced. The human vascular endothelial growth factor receptor 1 (VEGF-R1, ...
A new impedimetric biosensor utilizing VEGF receptor-1 (Flt-1): Early diagnosis of vascular endothelial growth factor in breast cancer
(Elsevier Advanced Technology, 2011)
A new impedimetric biosensor, based on the use of vascular endothelial growth factor receptor-1 (VEGF-R1), was developed for the determination of vascular endothelial growth factor (VEGF). VEGF-R1 was immobilized through ...
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker
(Elsevier, 2014)
A specific and sensitive biosensor was developed successfully for quantitative detection of human epidermal growth factor receptor by electrochemical impedance spectroscopy. Anti-human epidermal growth factor receptor ...
Ultrasensitive Impedimetric Biosensor Fabricated by a New Immobilisation Technique for Parathyroid Hormone
(Springer, 2015)
This paper presents a novel ultrasensitive and rapid impedimetric biosensor with new immobilisation materials for parathyroid hormone (PTH) with the aim to determine the PTH level in serum for the diagnosis and monitoring ...