Ara
Toplam kayıt 70, listelenen: 31-40
A novel immunosensor based on fullerene C60 for electrochemical analysis of heat shock protein 70
(Elsevier Science Sa, 2016)
This study illustrates the development of the biosensor for the determination of the heat shock protein 70 (HSP70). For this purpose, firstly the biosensor based on the glassy carbon electrode (GCE) was modified with ...
Ultrasensitive Impedimetric Biosensor Fabricated by a New Immobilisation Technique for Parathyroid Hormone
(Springer, 2015)
This paper presents a novel ultrasensitive and rapid impedimetric biosensor with new immobilisation materials for parathyroid hormone (PTH) with the aim to determine the PTH level in serum for the diagnosis and monitoring ...
An ITO Based Disposable Biosensor for Ultrasensitive Analysis of Retinol Binding Protein
(Wiley-V C H Verlag Gmbh, 2014)
A highly sensitive electrochemical biosensor based on anti-RBP biorecognition capable to analyze concentrations of retinol binding protein (RBP) was developed. The construction of the biosensor interfaces was carefully ...
A Novel Biosensing System Using Biological Receptor for Analysis of Vascular Endothelial Growth Factor
(Springer, 2014)
An immunosensor with rapid and ultrasensitive response for vascular endothelial growth factor (VEGF) has been built up with 4-aminothiophenol (4-ATP) onto the gold surfaces. Quantitative analysis of VEGF was performed by ...
Sulfite Determination by an Inhibitor Biosensor-based Mushroom (Agaricus Bisporus) Tissue Homogenate
(Informa Healthcare, 2012)
The aim of the study presented here is to develop a biosensor based on mushroom (Agaricus bisporus) tissue homogenate for sensitive and economical determination of sulfite in foods. The working principle of the biosensor ...
Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70
(Elsevier Science Bv, 2016)
In this study, it is aimed to design a label free immunosensor for determination of HSP70 (heat shock protein 70). Glassy carbon electrode was used as a working electrode. Graphene oxide was covered on the working electrode ...
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)
An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ...
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)
This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ...
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)
A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ...
Highly selective and sensitive sandwich immunosensor platform modified with MUA-capped GNPs for detection of spike Receptor Binding Domain protein: A precious marker of COVID-19 infection
(Elsevier B.V., 2021)
A label-free electrochemical biosensing system as a suitable analysis technique for COVID 19 specific spike receptor-binding domain protein (RBD) was developed with an aim to facilitate the diagnosis of coronavirus. A novel ...