Ara
Toplam kayıt 20, listelenen: 1-10
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ...
Ultrasensitive electrochemical detection of cancer associated biomarker HER3 based on anti-HER3 biosensor
(Elsevier, 2014)
The development of a new impedimetric biosensor for the detection of HER3, based on self-assembled monolayers (SAMs) of 4-aminothiophenol on gold electrodes, is reported. Anti-HER3 was used as a biorecognition element for ...
An impedimetric vascular endothelial growth factor biosensor-based PAMAM/cysteamine-modified gold electrode for monitoring of tumor growth
(Academic Press Inc Elsevier Science, 2012)
In the present work, we have developed a new biosensor based on fourth-generation (G4) PAMAM dendrimers for the analysis of vascular endothelial growth factor (VEGF). First, the PAMAM dendrimers were covalently attached ...
Development of an impedimetric aflatoxin M1 biosensor based on a DNA probe and gold nanoparticles
(Elsevier Advanced Technology, 2011)
The present work describes the construction and application of a new DNA biosensor for detection of aflatoxin M1. In order to immobilize a thiol-modified single stranded DNA (ss-HSDNA) probe that specifically bound aflatoxin ...
A novel, ultra sensible biosensor built by layer-by-layer covalent attachment of a receptor for diagnosis of tumor growth
(Elsevier, 2011)
In the presented research, a novel, ultra sensitive biosensor for the impedimetric detection of vascular endothelial growth factor (VEGF) is introduced. The human vascular endothelial growth factor receptor 1 (VEGF-R1, ...
A new impedimetric biosensor utilizing VEGF receptor-1 (Flt-1): Early diagnosis of vascular endothelial growth factor in breast cancer
(Elsevier Advanced Technology, 2011)
A new impedimetric biosensor, based on the use of vascular endothelial growth factor receptor-1 (VEGF-R1), was developed for the determination of vascular endothelial growth factor (VEGF). VEGF-R1 was immobilized through ...
Quantification of Trypsin Activity by a New Biosensing System Based on the Enzymatic Degradation and the Destructive Nature of Trypsin
(Springer, 2017)
Trypsin is an enzyme that is included in the hydrolysis class of enzymes. Trypsin catalyzes the cleavage of proteins from a serine residue and is found in the digestive system of vertebrates. The cystic fibrosis, which is ...
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker
(Elsevier, 2014)
A specific and sensitive biosensor was developed successfully for quantitative detection of human epidermal growth factor receptor by electrochemical impedance spectroscopy. Anti-human epidermal growth factor receptor ...
Ultrasensitive Impedimetric Biosensor Fabricated by a New Immobilisation Technique for Parathyroid Hormone
(Springer, 2015)
This paper presents a novel ultrasensitive and rapid impedimetric biosensor with new immobilisation materials for parathyroid hormone (PTH) with the aim to determine the PTH level in serum for the diagnosis and monitoring ...
A Novel Biosensing System Using Biological Receptor for Analysis of Vascular Endothelial Growth Factor
(Springer, 2014)
An immunosensor with rapid and ultrasensitive response for vascular endothelial growth factor (VEGF) has been built up with 4-aminothiophenol (4-ATP) onto the gold surfaces. Quantitative analysis of VEGF was performed by ...