Kategori "Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı" Rektörlüğe Bağlı Birimler İçin Listeleme
Toplam kayıt 60, listelenen: 1-20
-
Alloreactive memory B cell detection by flow cytometric cross match using polyclonally activated memory B cell culture supernatants
(Elsevier, 2022)In addition to alloantibodies, alloreactive memory B cell (mBC) evaluation has a potential for immunological risk assessment during transplantation processes. For the alloreactive mBCs evaluation currently, direct Flow ... -
A comparative study of short chain and long chain mercapto acids used in biosensor fabrication: A VEGF-R1-based immunosensor as a model system
(Taylor & Francis Ltd, 2016)A novel impedimetric biosensor utilizing a biological receptor, vascular endothelial growth factor receptor-1 (VEGF-R1), was developed for the determination of vascular endothelial growth factor (VEGF). VEGF-R1 was covalently ... -
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
Comparison of endoscopic diagnosis and histopathological results of patients with a preliminary diagnosis of malignancy and the role of the nurse in planning
(Mattioli 1885, 2020)Study Objectives: Endoscopy has become a gold standard for the diagnosis. In these procedures, pathologic help is taken for a definite diagnosis. An appointment is made according to the priorities of the patients applying ... -
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ... -
Copy number increase of oncoprotein CIP2A is associated with poor patient survival in human head and neck squamous cell carcinoma
(Wiley, 2016)BackgroundCIP2A, an inhibitor of PP2A tumour suppressor function, is a widely overexpressed biomarker of aggressive disease and poor therapy response in multiple human cancer types. MethodsCIP2A and DPPA4 copy number ... -
Detection of Kallikrein-Related Peptidase 4 with a Label-free Electrochemical Impedance Biosensor Based on a Zinc(II) Phthalocyanine Tetracarboxylic Acid-Functionalized Disposable Indium Tin Oxide Electrode
(Amer Chemical Soc, 2021)A new impedimetric biosensing system based on kallikrein-related peptidase 4 (KLK 4) antigen-specific antibodies and a zinc(II) phthalocyanine tetracarboxylic acid (Zn-PcTCa) matrix material was developed for the first ... -
Determination of calreticulin using Fe3O4@AuNPs core-shell functionalized with PT(COOH)(2) polymer modified electrode: A new platform for the impedimetric biosensing of cancer biomarkers
(Elsevier Science Sa, 2022)An innovative biosensing design strategy was utilized for the first time to develop a label-free and practical immunosensor for ultrasensitive analysis of calreticulin (CRT), a potential biomarker of breast carcinoma. ... -
The development of an ultra-sensitive electrochemical immunosensor using a PPyr-NHS functionalized disposable ITO sheet for the detection of interleukin 6 in real human serums
(Royal Soc Chemistry, 2020)A label-free impedimetric immunosensor based on a conjugated poly(pyrroleN-hydroxy succinimide) (PPyr-NHS) polymer covered disposable indium tin oxide electrode (ITO) was fabricated for the ultrasensitive determination of ... -
A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1 beta in human serum and saliva
(Elsevier Science Bv, 2018)In this study, we constructed a new and sensitive ITO based electrochemical immunosensor for detection of interleukin 1 beta(IL-1 beta), a cancer biomarker found in serum and saliva. 6-phosphonohexanoic acid (PHA) was used ... -
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
A Disposable, Highly Sensitive Biosensing System: Determination of Haptoglobin as a Significant Acute Phase Biomarker
(Bentham Science Publ Ltd, 2016)This paper presents a new disposable electrochemical biosensor for the analysis of Haptoglobin (Hp) which shows many important functionalities such as antioxidant capabilities, anti-inflammatory activities and regulation ... -
Effects of idiopathic erythrocytosis on the left ventricular diastolic functions and the spectrum of genetic mutations: A case control study
(Lippincott Williams & Wilkins, 2022)Background: We have aimed at exposing left ventricular diastolic functions and the presence of known genetic mutations for familial erythrocytosis, in patients who exhibit idiopathic erythrocytosis. Methods: Sixty-four ... -
The effects of polymorphisms in the CX3CR1 gene on the development of canine hip dysplasia
(TUBITAK, 2022)Hip dysplasia, caused by both environmental and genetic components, is a common disorder characterized by hip instability in humans and dogs. Unfortunately, the genetic mechanisms that cause the disease in both have not ... -
Electrochemical biosensors for hormone analyses
(Elsevier Advanced Technology, 2015)Electrochemical biosensors have a unique place in determination of hormones due to simplicity, sensitivity, portability and ease of operation. Unlike chromatographic techniques, electrochemical techniques used do not require ... -
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ... -
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ... -
Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
(Wiley-VCH Verlag, 2021)Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ...