A new method for diagnosis of anterior cruciate ligament tear: MRI with maximum flexion of knee in the prone position: A case control study
(Elsevier Ltd, 2019)
Background: The diagnosis of anterior cruciate ligament tear can be made by physical examination and magnetic resonance imaging (MRI) in the supine position. In cases where the tear is partially evaluated on MRI, the choice ...
Comparison of Cytotoxic Flow Cytometric Cross Match With Complement Dependent Lymphocytotoxicity and Flow Cytometric Cross Match in Renal Transplant Patients
(Elsevier USA, 2019)
Cytotoxic flow cytometric crossmatch (cFCXM), identified by detecting complement-mediated cytotoxic cell death in addition to the capability of showing the alloantibodies binding onto lymphocytes at the same time, can ...
Does anterolateral ligament rupture affect functional outcomes in patients who underwent an anterior cruciate ligament reconstruction?
(Elsevier Ltd, 2019)
Background: Studies have shown that the anterolateral ligament contributes to knee stability. This study aims to compare the results of postoperative physical examinations, knee joint stability tests, and functional ...
Phytoremediation of heavy metal-contaminated soil by switchgrass: A comparative study utilizing different composts and coir fiber on pollution remediation, plant productivity, and nutrient leaching
(MDPI AG, 2019)
We investigated the effects of organic amendments (thermophilic compost, vermicompost, and coconut coir) on the bioavailability of trace heavy metals of Zn, Cd, Pb, Co, and Ni from heavy metal-spiked soils under laboratory ...
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)
In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ...
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)
A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ...
Diagnostic Importance of Axial Loaded Magnetic Resonance Imaging in Patients with Suspected Lumbar Spinal Canal Stenosis
(Elsevier Inc., 2019)
Objective and Background: To study the efficacy of lumbar (AL) magnetic resonance imaging (MRI) in patients with suspected lumbar spinal stenosis (LSS), with and without AL compression. Supine MRI is used in the assessment ...
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...