A New, Sensitive and Disposable Electrochemical Immunosensor Based on Benzaldehyde Side Group Containing Phosphazene Polymer Modified ITO Substrate for Interleukin 1? Detection
dc.contributor.author | Aydın, Muhammet | |
dc.date.accessioned | 2022-05-11T14:48:05Z | |
dc.date.available | 2022-05-11T14:48:05Z | |
dc.date.issued | 2019 | |
dc.department | Rektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezi | |
dc.description.abstract | In this study, a novel electrochemical ultrasensitive immunosensor based on disposable benzaldehyde substituted phosp-hazene polymer (BSPP) modified ITO electrode was developed for interleukin 1? (IL 1?) detection. Aldehyde side groups containing phosphazene polymer (BSPP) synthesized via ring opening polymerization method. These aldehyde groups pro-vided anchoring points for anti-IL 1? antibodies. The production process of the proposed immunosensor was monitored by electrochemical techniques like Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV). In addition, these fabrication steps were characterized by utilizing Scanning Electron Microscopy (FE-SEM) and Atomic Force Micros-copy (AFM). Moreover, BSPP polymer layer on the polymer coated electrode surface was investigated by using Energy Dis-persive X-ray (EDX). The fabricated immunosensor had a low detection limit (9.3 fg/mL) and a wide linear detection range (0.03-7.5 pg/mL). Moreover, it had good reproducibility (1.82%), excellent repeatability (1.56%), good selectivity and high stability. The results of experiments showed that the BSPP polymer was desirable platform for IL 1? antigen detection in clinical diagnosis and practical applications. The applicability of the suggested biosensor was tested by measuring IL 1? level in human serum and the suggested immunosensor had acceptable results for quantitative analysis. | |
dc.identifier.doi | 10.15671/hjbc.515999 | |
dc.identifier.endpage | 315 | |
dc.identifier.issn | 1303-5002 | |
dc.identifier.issn | 2687-475X | |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 305 | |
dc.identifier.trdizinid | TXpnMU9UYzBOQT09 | |
dc.identifier.uri | https://doi.org/10.15671/hjbc.515999 | |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TXpnMU9UYzBOQT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11776/10597 | |
dc.identifier.volume | 47 | |
dc.indekslendigikaynak | TR-Dizin | |
dc.institutionauthor | Aydın, Muhammet | |
dc.language.iso | en | |
dc.relation.ispartof | Hacettepe Journal of Biology and Chemistry | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.title | A New, Sensitive and Disposable Electrochemical Immunosensor Based on Benzaldehyde Side Group Containing Phosphazene Polymer Modified ITO Substrate for Interleukin 1? Detection | |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 10597.pdf
- Boyut:
- 5.4 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text