Effect of cable cerclage on regional blood circulation in rabbits: a scintigraphic study

dc.authorid0000-0002-3053-9133
dc.authorid0000-0002-5772-5630
dc.authorscopusid26967708000
dc.authorscopusid35949526800
dc.authorscopusid56911998800
dc.authorscopusid57189868300
dc.authorscopusid6602904476
dc.authorwosidKarakoyun, Özgür/AAN-9431-2020
dc.authorwosidSahin, Ertan/AAG-8999-2020
dc.authorwosidkarakoyun, ozgur/G-9522-2013
dc.contributor.authorKarakoyun, Özgür
dc.contributor.authorŞahin, Ertan
dc.contributor.authorErol, Mehmet Fatih
dc.contributor.authorKarıksız, Mesut
dc.contributor.authorKüçükkaya, Metin
dc.date.accessioned2022-05-11T14:36:12Z
dc.date.available2022-05-11T14:36:12Z
dc.date.issued2016
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalı
dc.description.abstractPurpose. To evaluate changes in blood circulation of the femoral cortex in rabbits using scintigraphy before and after cable cerclage alone or combined with an intramedullary Kirschner wire. Method. Ten New Zealand rabbits were used. For the right femur, a 2-mm-thick cable was placed around the mid-diaphyseal region and squeezed with a 400-N force and locked with a clip. For the left femur, a 1.8-mm Kirschner wire was inserted retrogradely into the medullary canal, and a 2-mm-thick cable was applied using the same technique. The blood perfusion ratio of the region of interest (ROI) before and after surgery was evaluated using scintigraphy. Results. For the right femurs, the mean ROI perfusion ratio decreased by 45% from 2.51 to 1.37 after intervention (p=0.001). For the left femurs, the mean ROI perfusion ratio decreased by 56% from 2.12 to 0.92 after intervention (p<0.001). The mean ROI perfusion ratio post-intervention was higher in the right than left femurs (p=0.017). Conclusion. Cable cerclage around the femoral cortex significantly decreased blood circulation in the area.
dc.identifier.doi10.1177/1602400319
dc.identifier.endpage369
dc.identifier.issn1022-5536
dc.identifier.issn2309-4990
dc.identifier.issue3en_US
dc.identifier.pmid28031508
dc.identifier.scopus2-s2.0-85007597338
dc.identifier.scopusqualityQ2
dc.identifier.startpage367
dc.identifier.urihttps://doi.org/10.1177/1602400319
dc.identifier.urihttps://hdl.handle.net/20.500.11776/8408
dc.identifier.volume24
dc.identifier.wosWOS:000391162800019
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorKarakoyun, Özgür
dc.institutionauthorŞahin, Ertan
dc.institutionauthorErol, Mehmet Fatih
dc.institutionauthorKarıksız, Mesut
dc.language.isoen
dc.publisherHong Kong Acad Medicine Press
dc.relation.ispartofJournal of Orthopaedic Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectblood circulation
dc.subjectbone wires
dc.subjectfemur
dc.subjectradionuclide imaging
dc.subjectFixation
dc.titleEffect of cable cerclage on regional blood circulation in rabbits: a scintigraphic study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8408.pdf
Boyut:
379.04 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text