Characterization and treatment alternatives of industrial container and drum cleaning wastewater: Comparison of Fenton-like process and combined coagulation/oxidation processes

dc.authorid0000-0002-1457-1504
dc.authorid0000-0003-4827-5954
dc.authorscopusid14522763100
dc.authorscopusid57203097268
dc.authorscopusid23979891400
dc.authorscopusid25924353100
dc.authorwosidGüneş, Elçin/ABA-1276-2020
dc.authorwosidHANEDAR, ASUDE/ABA-4748-2020
dc.authorwosidGunes, Yalcin/ABA-1290-2020
dc.authorwosidGüneş, Elçin/ABA-2259-2020
dc.contributor.authorGüneş, Elçin
dc.contributor.authorDemir, Emre
dc.contributor.authorGüneş, Yalçın
dc.contributor.authorHanedar, Asude
dc.date.accessioned2022-05-11T14:17:27Z
dc.date.available2022-05-11T14:17:27Z
dc.date.issued2019
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Çevre Mühendisliği Bölümü
dc.description.abstractIndustrial container and drum cleaning (ICDC) facilities generated complex wastewater which have organic/inorganic compounds, acids, alkalis, metals, dyes, asbestos, PCBs, chemical cleaning solutions or textile auxiliary chemicals. Treatment of such these wastewaters containing all these pollutants is also very difficult. It is required that the wastewater chemical oxygen demand (COD) is below 1500 mg/L to treat in a centralized wastewater treatment facility in Thrace Region, Turkey. In this study the characterization of ICDC industrial wastewater and treatment alternatives of this wastewater using Fenton-like (FL) process, acidic coagulation-flocculation + H2O2/UV-C (CF + H2O2/UV-C) and acidic coagulation-flocculation + S2O82- (CF + S2O82-) processes have been studied. The existing treatment system already has a biological treatment system after coagulation-flocculation system and couldn't be operated effectively in spite of all the efforts. We have studied processes that can be integrated into the coagulation-flocculation (CF) process used in the existing wastewater treatment plant. According to characterization study, COD values were in the range of 4584-18125 mg/L. The COD of the wastewater used in treatment experiments were 11,853 mg/L. According to the results FL and CF + S2O82- systems were suitable for the COD discharge standards specified for the centralized wastewater treatment plant. The optimum conditions of FL process were 0.8 g/L for FeCl3 and 45 g/L for H2O2 and COD was measured as about 1500 mg/L at these doses. The optimum conditions of CF + S2O82- system were determined as 0.64 g/L FeCl3 for CF and 15 g/L H2O2 doses. At these dosages the highest COD removal efficiency was achieved to 68% after 5 h. All methods used were suitable for the removal of COD, biochemical oxygen demand (BOD), total organic carbon (TOC), total phosphorus (TP) and of some metals. Considering the integration into the existing treatment system and applicability, it is concluded that the FL process is most favorable.
dc.description.sponsorshipNKU-BAP [NKUBAP.00.17.YL.14.04]
dc.description.sponsorshipThis research was funded by NKU-BAP Project no: NKUBAP.00.17.YL.14.04.
dc.identifier.doi10.1016/j.seppur.2018.07.060
dc.identifier.endpage433
dc.identifier.issn1383-5866
dc.identifier.issn1873-3794
dc.identifier.scopus2-s2.0-85050498603
dc.identifier.scopusqualityQ1
dc.identifier.startpage426
dc.identifier.urihttps://doi.org/10.1016/j.seppur.2018.07.060
dc.identifier.urihttps://hdl.handle.net/20.500.11776/6361
dc.identifier.volume209
dc.identifier.wosWOS:000449133600048
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorGüneş, Elçin
dc.institutionauthorGüneş, Yalçın
dc.institutionauthorHanedar, Asude
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofSeparation and Purification Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectIndustrial container and drum cleaning
dc.subjectCOD removal
dc.subjectCoagulation-flocculation
dc.subjectFenton-like oxidation
dc.subjectPersulfate oxidation
dc.subjectAqueous-Solutions
dc.subjectPhoto-Fenton
dc.subjectActivated Persulfate
dc.subjectAdvanced Oxidation
dc.subjectHydroxyl Radicals
dc.subjectRefinery Effluent
dc.subjectLandfill Leachate
dc.subjectRemoval
dc.subjectDegradation
dc.subjectSulfate
dc.titleCharacterization and treatment alternatives of industrial container and drum cleaning wastewater: Comparison of Fenton-like process and combined coagulation/oxidation processes
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
6361.pdf
Boyut:
681.74 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text