A Retrospective Comparison of Computed Tomography and Fluoroscopic Guided Percutaneous Nephrostomy for Evaluating Radiation Exposure

dc.contributor.authorTürk, Yaşar
dc.contributor.authorDevecioğlu, İsmail
dc.date.accessioned2023-04-20T08:08:33Z
dc.date.available2023-04-20T08:08:33Z
dc.date.issued2021
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümü
dc.description.abstractAim: The study aimed to compare the radiation doses absorbed by the patient in first-time percutaneous nephrostomy under computed tomography (CT) and nephrostomy replacement under fluoroscopy. Material and Methods: Eighty-nine hydronephrotic patients referred for nephrostomy were included in this retrospective study. Seventy-five of these patients had the nephrostomy for the first-time under CT- guidance. Fourteen patients had the nephrostomy replacement operation under fluoroscopy guidance. Absorbed radiation doses were compared between these operations. Results: The groups showed no statistically significant differences in means of demography (age, sex, and pathology) and operational parameters (intervention side and complications) except the absorbed radiation dose. The median effective radiation doses were 1.18 mSv and 1.68 mSv for CT and fluoroscopy, respectively. The first-time nephrostomy operations under CT were completed with radiation doses significantly lower than those in nephrostomy replacement under fluoroscopy (p < 0.001). Conclusion: Ultra-low-dose and fast-acting CT-guided nephrostomy is a safe, user-friendly procedure that leads patients to less radiation exposure than expected.
dc.identifier.doi10.29058/mjwbs.852206
dc.identifier.endpage172
dc.identifier.issn2822-4302
dc.identifier.issn2587-0602
dc.identifier.issue2en_US
dc.identifier.startpage166
dc.identifier.trdizinid1109784
dc.identifier.urihttps://doi.org/10.29058/mjwbs.852206
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1109784
dc.identifier.urihttps://hdl.handle.net/20.500.11776/11348
dc.identifier.volume5
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorTürk, Yaşar
dc.institutionauthorDevecioğlu, İsmail
dc.language.isoen
dc.relation.ispartofBatı Karadeniz Tıp Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComputed tomography
dc.subjectFluoroscopy
dc.subjectHydronephrosis
dc.subjectNephrostomy
dc.subjectRadiation doseBilgisayarlı tomografi
dc.subjectFloroskopi
dc.subjectHidronefroz
dc.subjectNefrostomi
dc.subjectRadyasyon dozu
dc.titleA Retrospective Comparison of Computed Tomography and Fluoroscopic Guided Percutaneous Nephrostomy for Evaluating Radiation Exposure
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
11348.pdf
Boyut:
565.12 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text