Comparison of Various Measurement Methods in the Evaluation of Swelling After Third Molar Surgery

dc.contributor.authorKaplan, Volkan
dc.contributor.authorCiğerim, Levent
dc.contributor.authorÇınarsoy Ciğerim, Saadet
dc.contributor.authorBazyel, Zeynep Dilan
dc.contributor.authorDinç, Gönül
dc.date.accessioned2023-04-20T08:07:21Z
dc.date.available2023-04-20T08:07:21Z
dc.date.issued2021
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractObjective: This study aimed to examine the differences between 12 metric swelling evaluation methods in patients undergoing impacted lower third molar surgery. Material ve Methods: This study was conducted on the patients indicated for the extraction of impacted lower third molar teeth due to orthodontic reasons. Twenty-six patients aged between 18-40 were included in the study. Swelling levels after surgery were measured using anatomic landmarks used for the methods, and the distances between landmarks were measured before the operation, and on days 2 and 7 afterward. The measurements were done using thread and a millimeter ruler while patients were seated. The distances between the anatomical landmarks were evaluated by 12 different methods. Results: According to the results of the measurements performed on twenty-six patients, (15 male and 11 female) with a mean age of 23.85±6.06 years, male had more swelling than female and the difference was statistically significant (p<0.05) although age, and measurement methods had no significant effect on swelling (p>0.05). Conclusion: As a result of the present study; twelve swelling evaluation methods showed significantly similar results and the authors recommended using Method 1 and 5 for convenient clinical evaluation which could be performed with a smaller number of anatomical points.
dc.identifier.endpage420
dc.identifier.issn1300-2694
dc.identifier.issn2587-0351
dc.identifier.issue3en_US
dc.identifier.startpage412
dc.identifier.trdizinid1127373
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1127373
dc.identifier.urihttps://hdl.handle.net/20.500.11776/11267
dc.identifier.volume28
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorKaplan, Volkan
dc.language.isoen
dc.relation.ispartofVan Tıp Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleComparison of Various Measurement Methods in the Evaluation of Swelling After Third Molar Surgery
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
11267.pdf
Boyut:
1.45 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text