Hidrojen peroksit tayini için peroksidaz temelli poli-L-histidin modifiye camsı karbon enzim elektrot hazırlanması

dc.contributor.advisorÖztürk, Funda
dc.contributor.authorUlukan, Elif
dc.date.accessioned2024-10-29T18:44:40Z
dc.date.available2024-10-29T18:44:40Z
dc.date.issued2023
dc.departmentEnstitüler, Fen Bilimleri Enstitüsü, Kimya Ana Bilim Dalı
dc.descriptionFen Bilimleri Enstitüsü, Kimya Ana Bilim Dalı
dc.description.abstractBu çalışmada yaban turpu peroksidazının (HRP) çok duvarlı karbon nanotüp (MWCNT), iyonik sıvı (IL) ve poli-L-histidin (PLH) modifiye camsı karbon elektrot (GCE) üzerinde elektrostatik immobilizasyonuyla hidrojen peroksit (H2O2) tayini için yeni amperometrik biyosensör hazırlandı. Hazırlanan biyosensörün yüzey morfolojisi taramalı elektron mikroskobu (SEM) ve enerji dağılımlı X-ışını spektroskopisi (EDX), elektrokimyasal özellikleri dönüşümlü voltammetri (CV) ve elektrokimyasal empedans spektroskopisi (EIS) yöntemleri ile incelendi. En iyi analitik performansı elde etmek için elektrot bileşimi, tampon pH değeri ve çalışma potansiyeli optimize edildi. Optimum bileşimde hazırlanan modifiye elektrot, belirlenen optimum çalışma koşullarında 2,0×10-2 ?M – 9,1×10-1 ?M ve 1,80 ?M – 1,80×102 ?M olmak üzere iki farklı doğrusal çalışma aralığı sergiledi. Yöntemin gözlenebilme sınırı 2,9×10-3 ?M olarak belirlendi. Geliştirilen biyosensörün ticari oksijenli su örneğinde H2O2'nin amperometrik tayininde başarı ile uygulanabileceği belirlendi.
dc.description.abstractIn this study, a new amperometric biosensor for the determination of hydrogen peroxide (H2O2) was prepared by electrostatic immobilization of horseradish peroxidase (HRP) on a multi-walled carbon nanotube (MWCNT), ionic liquid (IL) and poly-L-histidine (PLH) modified glassy carbon electrode (GCE). The surface morphology of the prepared biosensor was examined by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX), and its electrochemical properties were examined by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. The electrode composition, buffer pH value and working potential were optimized to obtain the best analytical performance. The modified electrode prepared in optimum composition exhibited two different linear operating ranges of 2,0×10-2 ?M – 9,1×10-1 ?M and 1,80 ?M – 1,80×102 ?M at the optimum operating conditions. The limit of detection of the method was determined as 2,9×10-3 ?M. It has been determined that the developed biosensor can be successfully applied in the amperometric determination of H2O2 in commercial oxygenated water sample.
dc.identifier.endpage76
dc.identifier.startpage1
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=nLNfCsWgUluh5T2iyudShrjLqu897o1GSUPsABZRdRdL-75FrPPucFDZdNrZGLuM
dc.identifier.urihttps://hdl.handle.net/20.500.11776/15087
dc.identifier.yoktezid829845
dc.language.isotr
dc.publisherTekirdağ Namık Kemal Üniversitesi
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectKimya
dc.subjectChemistry
dc.titleHidrojen peroksit tayini için peroksidaz temelli poli-L-histidin modifiye camsı karbon enzim elektrot hazırlanması
dc.title.alternativePreparation of peroxidase-based poly-L-histidine modified glassy carbon enzyme electrode for hydrogen peroxide determination
dc.typeMaster Thesis

Files