Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKayhan, Arda
dc.contributor.authorPalabiyik, Figen
dc.contributor.authorSerinsoz, Serdar
dc.contributor.authorKiris, Adem
dc.contributor.authorBayramoğlu, Sibel
dc.contributor.authorWilliams, Joshua T. B.
dc.contributor.authorCimilli, Tan
dc.date.accessioned2022-05-11T14:40:59Z
dc.date.available2022-05-11T14:40:59Z
dc.date.issued2012
dc.identifier.issn0720-048X
dc.identifier.issn1872-7727
dc.identifier.urihttps://doi.org/10.1016/j.ejrad.2011.01.100
dc.identifier.urihttps://hdl.handle.net/20.500.11776/9009
dc.description.abstractObjective: To prospectively compare the efficacy of 40-row multidetector computed tomography angiography (MDCTA) and duplex ultrasonography (DUS) to diagnose mild peripheral arterial occlusive disease (PAOD) in lower leg and to search whether MDCTA can be used as a screening tool. Methods: Forty-three patients with intermittent claudication and leg pain, diagnosed as mild PAOD, had undergone DUS and MDCTA of lower limb. The arteries of lower leg were initially scanned by DUS, followed by MDCTA. Both modalities were compared for detecting the obstructed and stenotic segments. Results: A total of 774 vessel segments were imaged by both modalities. When all arteries were considered, MDCTA detected obstructed or stenotic lesions in 16.8% of arteries, versus 11.1% compared to DUS. When suprapopliteal arteries alone were considered, MDCTA detected lesions in 15.0% of arteries, versus 11.0% with DUS. When infrapopliteal arteries only were considered, MDCTA detected lesions in 19.6% of arteries, versus 11.3% with DUS. MDCTA showed 5.7% (95% CI: [3.5%, 7.9%]) more lesions than DUS when all arteries were considered together, 8.3% (95% CI: [4.6%, 12.0%]) more lesions when only the infrapopliteal arteries were compared, and 4.0% (95% CI: [1.3%, 6.8%]) more lesions when only suprapopliteal arteries were compared (p < 0.01 for all comparisons). Conclusion: 40-row MDCTA may be used as a screening tool in patients with mild lower extremity PAOD as it is a non-invasive and more accurate modality when compared to DUS. (C) 2011 Elsevier Ireland Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Ireland Ltden_US
dc.identifier.doi10.1016/j.ejrad.2011.01.100
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPeripheral arterial occlusive diseaseen_US
dc.subjectDuplex ultrasonographyen_US
dc.subjectMDCT angiographyen_US
dc.subjectDigital-Subtraction-Angiographyen_US
dc.subjectMultislice Spiral Cten_US
dc.subjectOcclusive Diseaseen_US
dc.subjectLower-Limben_US
dc.subjectAbdominal-Aortaen_US
dc.subjectArteriographyen_US
dc.subjectComplicationsen_US
dc.subjectMetaanalysisen_US
dc.subjectAccuracyen_US
dc.subjectSystemen_US
dc.titleMultidetector CT angiography versus arterial duplex USG in diagnosis of mild lower extremity peripheral arterial disease: Is multidetector CT a valuable screening tool?en_US
dc.typearticleen_US
dc.relation.ispartofEuropean Journal of Radiologyen_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalıen_US
dc.authorid0000-0001-7500-7707
dc.identifier.volume81en_US
dc.identifier.issue3en_US
dc.identifier.startpage542en_US
dc.identifier.endpage546en_US
dc.institutionauthorKayhan, Arda
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid25027835200
dc.authorscopusid25923075100
dc.authorscopusid26425288900
dc.authorscopusid54983797300
dc.authorscopusid24470980000
dc.authorscopusid56169783200
dc.authorscopusid24723731500
dc.authorwosidCimilli, Ahmet Tan/AAC-6411-2022
dc.identifier.wosWOS:000300408100064en_US
dc.identifier.scopus2-s2.0-84856956288en_US
dc.identifier.pmid21345629en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster