Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorVural, Metin
dc.contributor.authorErtaş, Gökhan
dc.contributor.authorOnay, Aslıhan
dc.contributor.authorAcar, Ömer
dc.contributor.authorEsen, Tarık
dc.contributor.authorSağlıcan, Yeşim
dc.contributor.authorAkpek, Sergin
dc.date.accessioned2022-05-11T14:16:01Z
dc.date.available2022-05-11T14:16:01Z
dc.date.issued2014
dc.identifier.issn2314-6133
dc.identifier.issn2314-6141
dc.identifier.urihttps://doi.org/10.1155/2014/768291
dc.identifier.urihttps://hdl.handle.net/20.500.11776/6149
dc.description.abstractIntroduction and Objective. Disadvantages associated with direct high b-value measurements may be avoided with use of computed diffusion-weighted imaging (cDWI). The purpose of this study is to assess the diagnostic performance of cDWI image sets calculated for high b-values of 1500, 2000, and 3000 s/mm(2). Materials and Methods. Twenty-eight patients who underwent multiparametric MRI of the prostate and radical prostatectomy consecutively were enrolled in this retrospective study. Using a software developed at our institute, cDWI 1500, cDWI 2000, and cDWI 3000 image sets were generated by fitting a monoexponential model. Index lesions on cDWI image sets were scored by two radiologists in consensus considering lesion conspicuity, suppression of background prostate tissue, distortion, image set preferability, and contrast ratio measurements were performed. Results. Lesion detection rates are the same for computed b-values of 2000 and 3000 s/ mm 2 and are better than b-values of 1500 s/ mm(2). Best lesion conspicuity and best background prostate tissue suppression are provided by cDWI(3000) image set. cDWI(2000) image set provides the best zonal anatomical delineation and less distortion and was chosen as the most preferred image set. Average contrast ratio measured on these image sets shows almost a linear relation with the b-values. Conclusion. cDWI 2000 image set with similar conspicuity and the same lesion detection rate, but better zonal anatomical delineation, and less distortion, was chosen as the preferable image set.en_US
dc.language.isoengen_US
dc.publisherHindawi Ltden_US
dc.identifier.doi10.1155/2014/768291
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectB-Valueen_US
dc.subject3 Ten_US
dc.subjectMrien_US
dc.titleConspicuity of Peripheral Zone Prostate Cancer on Computed Diffusion-Weighted Imaging: Comparison of cDWI(1500), cDWI(2000), and cDWI(3000)en_US
dc.typearticleen_US
dc.relation.ispartofBiomed Research Internationalen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.authorid0000-0003-3755-2397
dc.authorid0000-0002-3331-9152
dc.identifier.volume2014en_US
dc.institutionauthorZengingönül, Hale Pınar
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid8613764700
dc.authorscopusid6603605988
dc.authorscopusid56448889200
dc.authorscopusid8615400100
dc.authorscopusid6701527773
dc.authorscopusid36626227300
dc.authorscopusid6507039886
dc.authorwosidVural, Metin/AAD-2287-2020
dc.authorwosidErtas, G/AAG-8379-2019
dc.identifier.wosWOS:000347323500001en_US
dc.identifier.scopus2-s2.0-84918577908en_US
dc.identifier.pmid25525603en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster