Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAydın, Elif Burcu
dc.date.accessioned2022-05-11T14:07:24Z
dc.date.available2022-05-11T14:07:24Z
dc.date.issued2020
dc.identifier.issn0039-9140
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2020.120909
dc.identifier.urihttps://hdl.handle.net/20.500.11776/5095
dc.description.abstractA novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate cancer biomarker. IL 6 receptor was used as a biorecognition molecule and successfully immobilized by covalent linkage on the modified ITO electrode. Pyrrole monomer containing epoxy active side group was electropolymerized on the disposable ITO electrode for the first time and used as an immobilization matrix for IL 6 receptor. The designed biosensor fabrication stages were analyzed by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. For the quantification of IL 6 biomarker, EIS technique was utilized. In addition, the specific immuno-interaction between IL 6 receptor and IL 6 antigen was followed by single frequency impedance (SFI) technique. The resulting biosensor exhibited a linear calibration curve over the 0.02–16 pg/mL IL 6 concentration range, a limit of detection (LOD) of 6.0 fg/mL and a good selectivity against other interference biomarkers. Additionally, an excellent reproducibility, a long storage stability and an acceptable repeatability were found. The proposed impedimetric immunosensor was applied successfully to quantify for the IL 6 biomarker in human serum and it displayed a remarkable response in the real sample analysis with serum samples. In comparison with the commercial ELISA kit, the immunosensor provided a lower LOD and a lower analysis cost. In conclusion, the proposed impedimetric immunosensor could be clinically useful in the early diagnosis of the prostate cancer by detection of the serum samples after only simple dilution with phosphate buffer. © 2020 Elsevier B.V.en_US
dc.language.isoengen_US
dc.publisherElsevier B.V.en_US
dc.identifier.doi10.1016/j.talanta.2020.120909
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectImpedimetric immunosensoren_US
dc.subjectInterleukin 6en_US
dc.subjectProstate canceren_US
dc.subjectPyrrole-based conjugated polymer containing epoxy active side groupsen_US
dc.subjectAromatic compoundsen_US
dc.subjectConjugated polymersen_US
dc.subjectCyclic voltammetryen_US
dc.subjectDiagnosisen_US
dc.subjectDiseasesen_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectElectrodesen_US
dc.subjectImmunosensorsen_US
dc.subjectPolypyrrolesen_US
dc.subjectTin oxidesen_US
dc.subjectUrologyen_US
dc.subjectImmobilization matricesen_US
dc.subjectImpedimetric immunosensorsen_US
dc.subjectIndium tin oxide electrodesen_US
dc.subjectInterleukin-6en_US
dc.subjectLinear calibration curveen_US
dc.subjectModified ito electrodesen_US
dc.subjectProstate cancersen_US
dc.subjectSide groupsen_US
dc.subjectBiomarkersen_US
dc.subjectepoxideen_US
dc.subjectindium tin oxideen_US
dc.subjectinterleukin 6en_US
dc.subjectpolymeren_US
dc.subjectpolypyrroleen_US
dc.subjectpyrrole derivativeen_US
dc.subjecttin derivativeen_US
dc.subjecttumor markeren_US
dc.subjectchemistryen_US
dc.subjectelectrochemical analysisen_US
dc.subjectelectrodeen_US
dc.subjectgenetic proceduresen_US
dc.subjecthumanen_US
dc.subjectparticle sizeen_US
dc.subjectsurface propertyen_US
dc.subjectsynthesisen_US
dc.subjectBiomarkers, Tumoren_US
dc.subjectBiosensing Techniquesen_US
dc.subjectElectrochemical Techniquesen_US
dc.subjectElectrodesen_US
dc.subjectEpoxy Compoundsen_US
dc.subjectHumansen_US
dc.subjectInterleukin-6en_US
dc.subjectParticle Sizeen_US
dc.subjectPolymersen_US
dc.subjectPyrrolesen_US
dc.subjectSurface Propertiesen_US
dc.subjectTin Compoundsen_US
dc.titleHighly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrodeen_US
dc.typearticleen_US
dc.relation.ispartofTalantaen_US
dc.departmentRektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezien_US
dc.identifier.volume215en_US
dc.institutionauthorAydın, Elif Burcu
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57194273220
dc.identifier.wosWOS:000528209200023en_US
dc.identifier.scopus2-s2.0-85081679297en_US
dc.identifier.pmid32312453en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster