Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSoydan, Cihan
dc.contributor.authorYüksel, Ercan
dc.contributor.authorİrtem, Erdal
dc.date.accessioned2022-05-11T14:03:06Z
dc.date.available2022-05-11T14:03:06Z
dc.date.issued2020
dc.identifier.issn0267-7261
dc.identifier.urihttps://doi.org/10.1016/j.soildyn.2020.106167
dc.identifier.urihttps://hdl.handle.net/20.500.11776/4608
dc.description.abstractSingle-storey precast reinforced concrete (RC) frame type buildings are mainly preferred in manufacturing plants and storehouses. The behaviour of semi-rigid beam-column connections of the buildings is one of the main sources of uncertainty. The common damages observed after credible earthquakes were falling off large-span beams and large plastic deformations at the column base. New generation Lead Extrusion Damper (LED) developed by the authors is utilized in the seismic retrofitting of these buildings in use. This paper discusses the seismic performances of pre- and post-behaviour of the retrofitted buildings and evaluates the efficiency of the applied retrofitting technique. It is exposed that seismic demands are diminished essentially. The relative storey drifts decrease by about 40-90% while the reduction in the strain at the column base section reaches to 70%. © 2020 Elsevier Ltden_US
dc.language.isoengen_US
dc.publisherElsevier Ltden_US
dc.identifier.doi10.1016/j.soildyn.2020.106167
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectColumn type structureen_US
dc.subjectLead extrusion damperen_US
dc.subjectManufacturing plantsen_US
dc.subjectPinned beam-to-column connectionsen_US
dc.subjectPrecast structuresen_US
dc.subjectRetrofittingen_US
dc.subjectSeismic performanceen_US
dc.subjectConcrete constructionen_US
dc.subjectOffice buildingsen_US
dc.subjectPrecast concreteen_US
dc.subjectRetrofittingen_US
dc.subjectSeismic wavesen_US
dc.subjectSeismologyen_US
dc.subjectIndustrial buildingsen_US
dc.subjectLarge plastic deformationen_US
dc.subjectLead extrusion dampersen_US
dc.subjectManufacturing planten_US
dc.subjectPrecast reinforced concreteen_US
dc.subjectSeismic Performanceen_US
dc.subjectSeismic retrofittingen_US
dc.subjectSources of uncertaintyen_US
dc.subjectReinforced concreteen_US
dc.subjectcolumnen_US
dc.subjectmultistorey buildingen_US
dc.subjectreinforced concreteen_US
dc.subjectseismic responseen_US
dc.subjectseismic retrofiten_US
dc.subjectstrainen_US
dc.titleSeismic performance improvement of single-storey precast reinforced concrete industrial buildings in useen_US
dc.typearticleen_US
dc.relation.ispartofSoil Dynamics and Earthquake Engineeringen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.identifier.volume135en_US
dc.institutionauthorSoydan, Cihan
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid56044898600
dc.authorscopusid55607011600
dc.authorscopusid21740569200
dc.identifier.wosWOS:000540376000018en_US
dc.identifier.scopus2-s2.0-85084108248en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster