Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorİlten, Nadir
dc.contributor.authorTecer, Lokman Hakan
dc.contributor.authorSelici, Ayşe Tulay
dc.date.accessioned2022-05-11T14:03:02Z
dc.date.available2022-05-11T14:03:02Z
dc.date.issued2016
dc.identifier.issn1018-4619
dc.identifier.issn1610-2304
dc.identifier.urihttps://hdl.handle.net/20.500.11776/4584
dc.description.abstractIn recent years, there has been much research on indoor air quality, owing to a growing interest in improvement of air quality in residential buildings. People spend most of their time indoors, where air quality is affected by many factors such as location and structure of housing, ventilation systems, and comfort parameters. CO2 and other indoor gas concentrations are important indicators of indoor air quality. The aim of this study is to determine the effects of various factors such as location and characteristics of housing and smoking status on carbon dioxide (CO2) concentrations and air exchange rates in 29 representative buildings in Balikesir, Turkey. CO2 concentrations were measured using a non-dispersive infrared method, air changes per hour (ACH) were estimated using a CO2 balance method, and other parameters were recorded. Mean CO2 concentrations were 667 and 1011 ppm in summer and winter, respectively. Estimated mean air exchange rates were 1.04 and 0.70 ACH in summer and winter, respectively. The analysis showed that CO2 concentrations and ACH were affected by the area of houses, season, ventilation systems and ventilation duration. CO2 concentrations in winter were higher in all buildings relative to summer in the residential area. Air exchange rates were primarily affected by duration of ventilation, house area, distances to main roads, and smoking status.en_US
dc.language.isoengen_US
dc.publisherParlar Scientific Publications (P S P)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectair change rateen_US
dc.subjectcarbon dioxideen_US
dc.subjectindoor air qualityen_US
dc.subjectresidential buildingen_US
dc.subjectBalikesiren_US
dc.subjectTurkeyen_US
dc.subjectIndoor Airen_US
dc.subjectNatural Ventilationen_US
dc.subjectRatesen_US
dc.titleCALCULATION AND TEMPORAL VARIABILITY OF VENTILATION COEFFICIENT DEPENDING ON LOCATION AND CHARACTERISTICS OF HOUSES IN BALIKESIR CITY CENTERen_US
dc.typearticleen_US
dc.relation.ispartofFresenius Environmental Bulletinen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Çevre Mühendisliği Bölümüen_US
dc.identifier.volume25en_US
dc.identifier.issue5en_US
dc.identifier.startpage1562en_US
dc.identifier.endpage1574en_US
dc.institutionauthorTecer, Lokman Hakan
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidTECER, Lokman Hakan/ABA-7380-2020
dc.identifier.wosWOS:000378967600031en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster