Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorYıldız, Tülin
dc.contributor.authorYazıcı, Cenk Murat
dc.contributor.authorTürker, Polat
dc.contributor.authorÖnler, Ebru
dc.contributor.authorMalak, Arzu
dc.contributor.authorEren, Elif
dc.date.accessioned2022-05-11T14:02:44Z
dc.date.available2022-05-11T14:02:44Z
dc.date.issued2020
dc.identifier.issn2459-1459
dc.identifier.issn2459-1459
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.597753
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TkRjeU16WXhNUT09
dc.identifier.urihttps://hdl.handle.net/20.500.11776/4464
dc.description.abstractObjective: The aim of this study is to evaluate and compare the accuracy of urine output measurement performed by standard urine bags and urofix. Methods: This is a prospective study conducted at a 22-bed urology unit. Urine volume was measured either by a standard urine bag or urofix, verified by scaled container measurements in patients dressed with urinary catheter and expected to stay with it for 24 hours or more. In total, 1048 measurements were obtained for 131 patients. Results: The difference between median, maximum and minimum values of urine volumes from the scaled container and nurse’s forecast was evaluated for each of 4 measurements. When the urine volume was measured with the standard urine bag, the average volume was 550 cc in the first measurement while it was 300 cc with urofix. Mean values for the second, third and fourth measurements with standard urine bag and urofix were as follows respectively; 590 cc and 335 cc, 500 cc and 300 cc, 600 cc and 300 cc. The difference was statistically significant in all measurements (p<0.001). Conclusion: In this study, urofix was the most reliable method for measuring urine output and fluid management. Furthermore, if the patient has a standard urine bag, it is recommended to confirm the urine output with a scaled container.en_US
dc.language.isoengen_US
dc.identifier.doi10.33808/clinexphealthsci.597753
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleIs Standard Urine Bag or Urofix? Which is More Usefull in Surgical Nursing Care? Accuracy of Urine Output Monitoringen_US
dc.typearticleen_US
dc.relation.ispartofClinical and Experimental Health Sciencesen_US
dc.departmentYüksekokullar, Sağlık Yüksekokulu, Hemşirelik Bölümüen_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Üroloji Ana Bilim Dalıen_US
dc.departmentMeslek Yüksekokulları, Sağlık Hizmetleri Meslek Yüksekokulu, Sağlık Bakım Hizmetleri Bölümüen_US
dc.identifier.volume10en_US
dc.identifier.issue4en_US
dc.identifier.startpage423en_US
dc.identifier.endpage427en_US
dc.institutionauthorYıldız, Tülin
dc.institutionauthorYazıcı, Cenk Murat
dc.institutionauthorTürker, Polat
dc.institutionauthorÖnler, Ebru
dc.institutionauthorMalak, Arzu
dc.institutionauthorEren, Elif
dc.identifier.wosWOS:000604683100015en_US
dc.identifier.trdizinidTkRjeU16WXhNUT09en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster