Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖztürk, Funda
dc.contributor.authorBarsbuğa, Rüveyda
dc.date.accessioned2016-09-27T06:26:08Z
dc.date.available2016-09-27T06:26:08Z
dc.date.issued2016
dc.identifier.otherNKU BAP. 00.10.AR.12.12
dc.identifier.urihttps://hdl.handle.net/20.500.11776/41
dc.description.abstractElektrokimyasal yöntemler, farklı yükseltgenme basamağına sahip türlerin tayini çalışmalarında yaygın biçimde kullanılmaktadır. Bu çalışmada ürik asidin elektrokimyasal davranışı alüminyum oksit nanopartikülleri ile modifiye edilmiş karbon pasta elektrotta 0,05 M fosfat tamponu ortamında dönüşümlü voltametri ve kare dalga voltametri yöntemleri ile incelendi. Ürik asidin adsorpsiyon özellikleri incelenerek yükseltgenme reaksiyonunda aktarılan elektron sayısı hesaplanarak alüminyum oksit nanopartiküllü karbon pasta elektrot yüzeyinde olası reaksiyon mekanizması önerildi. Ayrıca ürik asidin serum örneklerinde tayini için kare dalga voltametri yöntemi geliştirildi. Bu yöntem ile elde edilen pik akımı-derişim grafiklerinden doğrusal çalışma aralığı 1,0 × 10-7 mol L-1 - 2,2 × 10-4 mol L-1 olarak belirlendi. Yapılan kalibrasyon çalışmalarının analitik parametreleri en küçük kareler yöntemi ile değerlendirildi ve gözlenebilme sınırı ve alt tayin sınırı değerleri belirlendi. Geliştirilen yöntemin validasyonu yapıldı. Aluminyum oksit nanopartiküllü karbon pasta elektrot cevaplarına biyolojik ortamlarda bulunan ve girişim yapan türlerin etkisi incelendi. Geliştirilen kare dalga voltametri yöntemi serum ortamında bulunan ürik asidin tayini için kullanıldığında; güvenilir, tekrarlanabilir, yüksek doğruluk ve kesinliğe sahip sonuçlar elde edildi.en_US
dc.description.abstractElectrochemical methods are widely used for the determination of electroactive compounds at different oxidation steps. In this study, the electrochemical behaviour of uric acid at aluminium oxide nanoparticles modified carbon paste electrode was investigated in 0.05 M phosphate buffer solution by cyclic voltammetry and square wave voltammetry. Adsorption properties of uric acid was investigated and the electrons transferred in the oxidation reaction was calculated to suggest the possible reaction mechanism at the aluminium oxide nanoparticles modified carbon paste electrode. Moreover, square wave voltammetric method was developed for the determination of uric acid in serum samples. The linear working range of this method was calculated from the peak current-concentration graph was found as 1.0×10-7 molL-1–2.4×10-3 molL-1. The analytical parameters of the calibration studies were evaluated by the least squares method and limit of detection and limit of quantification values were calculated for the developed method and the developed method was validated. The interference effect of the common species found in biological media to aluminium oxide nanoparticles modified carbon paste electrode response was also studied. The presented square wave voltammetric method was applied to the determination of uric acid in serum samples and reliable, reproducible, accurate and precise results were obtained.en_US
dc.language.isoturen_US
dc.publisherNamık Kemal Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKarbon pasta elektroten_US
dc.subjectnanopartikülen_US
dc.subjectürik asiten_US
dc.subjectaskorbik asiten_US
dc.subjectkare dalga voltametrien_US
dc.subjectCarbon paste electrodeen_US
dc.subjectnanoparticlesen_US
dc.subjecturic aciden_US
dc.subjectascorbic aciden_US
dc.subjectsquare wave voltammetryen_US
dc.titleAskorbik asit varlığında aluminyum oksit nanopartikülleri ile modifiye edilmiş karbon pasta elektrotta ürik asit tayinien_US
dc.typeprojecten_US
dc.departmentFakülteler, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.authoridTR58846en_US
dc.relation.publicationcategoryProjeen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster