Ara
Toplam kayıt 32, listelenen: 21-30
A Comparative Study of Redox Parameters and Electrochemical Impedance Spectroscopy of Polycarbazole Derivatives on Carbon Fiber Microelectrode
(Korean Fiber Soc, 2010)
In this study, N-Carbazole and its derivatives (N-Vinylcarbazole, N-Ethylcarbazole, N-Vinylbenzylcarbazole, and N-Benzylcarbazole) were electrochemically polymerized on carbon fiber microelectrodes (diameter similar to 7 ...
Monomer Concentration Effects of Poly (3-methylthiopene) on Electrochemical Impedance Spectroscopy
(Esg, 2009)
Poly(3-methylthiophene) (PMT) doped with perchlorate anion was prepared electrochemically in the presence of sodium perchlorate (ClO4-) salt as the supporting electrolyte. The effect of current density, various initial ...
Glucose oxidase immobilization onto Au/poly[anthranilic acid-co-3-carboxy-N-(2-thenylidene)aniline]/PVAc electrospun nanofibers
(Springer, 2017)
Au/poly[anthranilic acid-co-3-carboxy-N-(2-thenylidene)aniline/PVAc] [Au/P(ANA-co-CNTA)/PVAc] electrospun nanofibers were fabricated in different electrospinning media including acetone and dimethylformamide (DMF) for ...
Quantification of Trypsin Activity by a New Biosensing System Based on the Enzymatic Degradation and the Destructive Nature of Trypsin
(Springer, 2017)
Trypsin is an enzyme that is included in the hydrolysis class of enzymes. Trypsin catalyzes the cleavage of proteins from a serine residue and is found in the digestive system of vertebrates. The cystic fibrosis, which is ...
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker
(Elsevier, 2014)
A specific and sensitive biosensor was developed successfully for quantitative detection of human epidermal growth factor receptor by electrochemical impedance spectroscopy. Anti-human epidermal growth factor receptor ...
Electrochemical copolymerization of carbazole and 2,2 ':5 '-2 '' terthiophene: characterization and micro-capacitor application
(Springer, 2014)
In this paper, a copolymer of carbazole (Cz) and 2,2':5',2 ''-terthiophene (TTh) was electropolymerized in 0.1 M sodium perchlorate (NaClO4)/acetonitrile (CH3CN) on glassy carbon electrode. The optimum conditions of resulting ...
Ultrasensitive Impedimetric Biosensor Fabricated by a New Immobilisation Technique for Parathyroid Hormone
(Springer, 2015)
This paper presents a novel ultrasensitive and rapid impedimetric biosensor with new immobilisation materials for parathyroid hormone (PTH) with the aim to determine the PTH level in serum for the diagnosis and monitoring ...
Comparison of electrolyte effects for poly(3,4-ethylenedioxythiophene) and poly(3-octylthiophene) by electrochemical impedance spectroscopy and polymerization parameters with morphological analyses on coated films
(Springer, 2013)
3,4-Ethylenedioxythiophene and 3-octylthiophene were electropolymerized on glassy carbon electrodes (GCE) to compare with four different electrolytes [lithium perchlorate (LiClO4), sodium perchlorate, tetraethylammonium ...
Nanocomposite film formations of polyaniline via TiO2, Ag, and Zn, and their corrosion protection properties
(Elsevier Science Sa, 2015)
Polyaniline (PAN!) and its nanocomposites containing TiO2, Ag, and Zn were electrocoated on an Al1050 electrode by cyclic voltammetry. The modified polymer and the nanocomposite films were characterized by cyclic voltammetry ...
Monomer concentration effect on electrochemically modified carbon fiber with poly[1-(4-methoxyphenyl)-1H-pyrrole] as microcapacitor electrode
(2009)
In this study, films of poly[1-(4-methoxyphenyl)-1H-pyrrole] [poly(MPPy)] were electrochemically grown on carbon fiber microelectrodes (CFMEs) in 0.05 M of tetraethyl ammonium perchlorate-dichloromethane. The effect of ...