Ara
Toplam kayıt 7, listelenen: 1-7
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)
An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ...
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)
This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ...
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
(Elsevier B.V., 2021)
An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ...
An ultrasensitive immunosensor based on tri-armed star poly(glycidyl methacrylate) polymer-coated ITO-PET electrode for detection of neuron-specific enolase in human serum
(Taylor and Francis Ltd., 2020)
In the present study, an ultrasensitive and simple impedimetric biosensor was fabricated for the determination of neuron-specific enolase (NSE) cancer biomarker. Anti-NSE antibody was covalently immobilised on the indium ...
A label-free and sensitive impedimetric immunosensor for TNF ? biomarker detection based on epoxysilane-modified disposable ITO-PET electrode
(Taylor and Francis Ltd., 2020)
The present study constructed a simple and cost-effective electrochemical immunosensor based on 3-glycidoxypropyltriethoxysilane (GPTES) monolayer coated indium tin oxide-polyethylene terephthalate (ITO-PET) electrode for ...
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...