Ara
Toplam kayıt 8, listelenen: 1-8
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
(Elsevier B.V., 2020)
A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ...
Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode
(Elsevier B.V., 2020)
An ultrasensitive, specific and label-free immunosensor was developed to determine the lowest alteration of neuron specific enolase antigen (NSE), the standard biomarker of lung cancer patients. This immunosensor was the ...
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
(Elsevier B.V., 2021)
This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium ...
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
(Elsevier B.V., 2020)
A novel impedimetric immunosensor based on conjugated succinimide group substituted polythiophene polymer (SucS-PThi) modified indium tin oxide (ITO) electrode was fabricated for ultra-sensitive and ultra-selective ...
An ultrasensitive immunosensor based on tri-armed star poly(glycidyl methacrylate) polymer-coated ITO-PET electrode for detection of neuron-specific enolase in human serum
(Taylor and Francis Ltd., 2020)
In the present study, an ultrasensitive and simple impedimetric biosensor was fabricated for the determination of neuron-specific enolase (NSE) cancer biomarker. Anti-NSE antibody was covalently immobilised on the indium ...
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)
Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ...
A label-free and sensitive impedimetric immunosensor for TNF ? biomarker detection based on epoxysilane-modified disposable ITO-PET electrode
(Taylor and Francis Ltd., 2020)
The present study constructed a simple and cost-effective electrochemical immunosensor based on 3-glycidoxypropyltriethoxysilane (GPTES) monolayer coated indium tin oxide-polyethylene terephthalate (ITO-PET) electrode for ...
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...