Ara
Toplam kayıt 50, listelenen: 21-30
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)
A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ...
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
(Elsevier B.V., 2020)
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ...
An ultrasensitive immunosensor based on tri-armed star poly(glycidyl methacrylate) polymer-coated ITO-PET electrode for detection of neuron-specific enolase in human serum
(Taylor and Francis Ltd., 2020)
In the present study, an ultrasensitive and simple impedimetric biosensor was fabricated for the determination of neuron-specific enolase (NSE) cancer biomarker. Anti-NSE antibody was covalently immobilised on the indium ...
A Label-free Electrochemical Immunosensor for Highly Sensitive Detection of TNF alpha, Based on Star Polymer-modified disposable ITO Electrode
(Bentham Science Publ Ltd, 2021)
Background: Biomarkers are very important disease-related biomolecules which should be analyzed sensitive and selective in related physiological fluids or tissues. Tumor necrosis factor-alpha is a type of cytokine which ...
A Hybrid Enzyme Biosensor Based on Sulfite Oxidase and Glucose Oxidase for the Analyzing of Sulfite and Glucose
(Univ Tehran, Fac Chemistry, Center Excellence Electrochemistry, 2012)
In this study, we developed a hybrid biosensor based on sulfite oxidase and glucose oxidase for determination of sulfite and glucose. The principle of the measurements was based on the determination of the decrease in the ...
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
(Elsevier Advanced Technology, 2018)
A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ...
Copy number increase of oncoprotein CIP2A is associated with poor patient survival in human head and neck squamous cell carcinoma
(Wiley, 2016)
BackgroundCIP2A, an inhibitor of PP2A tumour suppressor function, is a widely overexpressed biomarker of aggressive disease and poor therapy response in multiple human cancer types. MethodsCIP2A and DPPA4 copy number ...
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)
In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ...
A Novel Mutation in the Promoter Region of the -Globin Gene: HBB: c.-127G > C
(Taylor & Francis Ltd, 2016)
Novel -globin gene mutations are still occasionally being reported, especially when evaluating milder phenotypes. We report here a novel putative mutation in the promoter region of the -globin gene and assess its clinical ...
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)
Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ...