Ara
Toplam kayıt 11, listelenen: 1-10
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ...
Sığırlarda Kalpain ve Kalpastatin Gen Polimorfizmlerinin Et Tekstürünün İyileştirilmesi Çalışmalarında Kullanımı
(2019)
Son yıllarda, tüketici tercihleri doğrultusunda et tekstürünün iyileştirilmesi konusuna ilgi artmış ve özellikte etçisığır ırklarında bu özelliğini iyileştirilmesine yönelik çalışmalar yapılmıştır. Etin gevrekliğinden üç ...
Immobilization techniques of nanomaterials
(Elsevier, 2019)
In recent years, nanomaterials have been widely utilized for the fabrication of biosensors and sensors due to their prominent features, such as high conductivity, large surface area, and excellent mechanical and optical ...
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)
In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ...
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)
A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ...
A Sensitive and Label-Free Electrochemical Impedance Immunosensor for CDH 22 Biomarker Detection Based on Organo-Functional Silane Modified ITO Electrode
(2019)
In this work, a novel electrochemical label free immunosensor was fabricated for Cadherin-like protein 22 (CDH 22) biomarker detection based on specific immunoreaction between anti-CDH 22 antibody and CDH 22 antigen. The ...
A New, Sensitive and Disposable Electrochemical Immunosensor Based on Benzaldehyde Side Group Containing Phosphazene Polymer Modified ITO Substrate for Interleukin 1? Detection
(2019)
In this study, a novel electrochemical ultrasensitive immunosensor based on disposable benzaldehyde substituted phosp-hazene polymer (BSPP) modified ITO electrode was developed for interleukin 1? (IL 1?) detection. Aldehyde ...
Advances in electrochemical immunosensors
(Elsevier Academic Press Inc, 2019)
Immunosensors are compact tools on which antibody and antigen interactions are formed. The specific interaction between antibody and antigen is detected by using a transducer and an electrical signal is measured. This ...
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)
A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ...
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
(Elsevier Ltd, 2019)
A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...