Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKılıç, Havvanur
dc.contributor.authorBiçer, Perihan
dc.contributor.authorBozkurt, Sercan
dc.date.accessioned2023-05-06T17:19:39Z
dc.date.available2023-05-06T17:19:39Z
dc.date.issued2023
dc.identifier.issn2076-3417
dc.identifier.urihttps://doi.org/10.3390/app13053040
dc.identifier.urihttps://hdl.handle.net/20.500.11776/11916
dc.description.abstractThe induced trench installation method is applied by placing material with high compressibility on rigid pipes to reduce the earth pressures acting on them. Although the performance of this method for rigid pipes has been investigated, research on thermoplastic pipes is very limited. In this study, induced trench installation (ITI) and embedded trench installation (ETI) of large-diameter thermoplastic pipes subjected to high fill stresses were investigated by numerical analysis. The numerical model has been verified by considering the field experiments, and a series of analyses were carried out by placing Expanded Polystyrene Foam (EPS Geofoam) in ITI and ETI models. Pipe stresses and deflections were evaluated by considering the pipe diameter, stiffness, and backfill properties. The ITI and ETI models in thermoplastic pipes reduced the stresses acting on the pipes and increased the positive arching regardless of the deflection of the pipe. For pipes with an inner diameter of 0.762 to 1.524 m under 30 m of fill stress, approximately 1.5 to 3.0% deflection occurred. In the ETI model, the horizontal earth pressure in the spring line of the pipe decreased from 65 to 40% depending on the backfill type, and an approximately uniform stress distribution was formed around the pipe.en_US
dc.language.isoengen_US
dc.publisherMdpien_US
dc.identifier.doi10.3390/app13053040
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectthermoplastic pipeen_US
dc.subjectnumerical analysisen_US
dc.subjectEPS Geofoamen_US
dc.subjectsoil archingen_US
dc.subjectembedded trenchen_US
dc.subjectinduced trenchen_US
dc.subjectSoil-Structure Interactionen_US
dc.subjectDensity Polyethylene Pipeen_US
dc.subjectField Performanceen_US
dc.subjectEps Geofoamen_US
dc.subjectEarth Pressuresen_US
dc.subjectBuried Pipesen_US
dc.subjectBox Culvertsen_US
dc.subjectHdpe Pipesen_US
dc.subjectReductionen_US
dc.subjectDesignen_US
dc.titleA Numerical Investigation of Induced and Embedded Trench Installations for Large-Diameter Thermoplastic Pipes under High Fill Stressesen_US
dc.typearticleen_US
dc.relation.ispartofApplied Sciences-Baselen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.identifier.volume13en_US
dc.identifier.issue5en_US
dc.institutionauthorBiçer, Perihan
dc.institutionauthorBozkurt, Sercan
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.wosWOS:000946872100001en_US
dc.identifier.scopus2-s2.0-85149967406en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster