An experimental comparison of radiant wall and ceiling cooling system integrated with ground source heat pump and direct expansion fan coil system in a highly glazed office room
Özet
Hydronic radiant systems, which provide a thermal comfort environment, come to the fore in different building applications due to their energy saving potential and being integrated with renewable energy systems. The aim of this study is to present a full-scale experiment to compare the thermal comfort performances of radiant ceiling, wall and wall + ceiling systems coupled ground source heat pump and direct expansion fan coil system implemented in Yildiz Technical University Science and Technology Application and Research Center, Istanbul, Turkey. Air velocity, horizontal and vertical air temperature differences, mean radiant temperature and humidity values, which are four physical parameters that can affect the thermal satisfaction of office workers for 9 different experimental conditions, are measured for fan coil and all radiant systems. The results indicate that vertical temperature differences between ankle and head level vary from 0.9 °C to 1.4 °C for both fan coil system and all radiant system configurations in different location of the test room. Acceptable overall comfort in indoor environments Class A only showed stable performance with an average of 0.12 PMV and 5.3 % PPD when ceiling + wall radiant panels were actively cooled. The result shows that the difference between room air temperature and room operating temperature varies between 0.45 °C and 0.6 °C when cooling loads are met by radiant systems. This may not make it possible to use indoor air temperature instead of indoor operating temperature in the control of radiant systems. Moreover, the thermal environment of the radiant system are more uniform than fan coil system due to low air temperature stratification, air velocity and small differences between mean radiant temperature and indoor air temperature. © 2022 Elsevier B.V.
Cilt
273Koleksiyonlar
İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
Sigmoid based PID controller implementation for rotor control
Ateş, A.; Alagöz, Barış Baykant; Yeroglu, C.; Alisoy, Hafız (Institute of Electrical and Electronics Engineers Inc., 2015)This paper presents a sigmoid based variable coefficient PID (SBVC-PID) controller design for Twin Rotor MIMO System (TRMS). The proposed SBVC-PID controller dynamically changes controller coefficients according to a ... -
Computer Aided Design of PID Control of Pulse DC Sintering System
Yener, Tuba; Yener, Şuayb Çağrı; Mutlu, Reşat (Institute of Electrical and Electronics Engineers Inc., 2019)Pulse DC sintering (PDCS) systems, an effective way of producing sintered materials, are complex systems. They need to be modelled both electrically and thermally. Such a system can be controlled manually or automatically. ... -
Fuzzy cognitive maps based decision support system for renewable energy investments
Hasan, D.; Sağbaş, Aysun; Çapraz, Ozan (Computers and Industrial Engineering, 2014)Today, renewable energy sources such as hydropower, biomass, geothermal, solar and wind play a major role in meeting the energy requirements in terms of economics and politics aspects for any country. The selection of the ...