Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAydın, Elif Burcu
dc.contributor.authorSezgintürk, Mustafa Kemal
dc.date.accessioned2022-05-11T14:48:13Z
dc.date.available2022-05-11T14:48:13Z
dc.date.issued2018
dc.identifier.issn0003-2697
dc.identifier.issn1096-0309
dc.identifier.urihttps://doi.org/10.1016/j.ab.2018.05.030
dc.identifier.urihttps://hdl.handle.net/20.500.11776/10614
dc.description.abstractIn this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first employed to cancer biomarker sensing platform. Anti-IL-8 antibody was used as a biorecognition element and the detection principle of this immunosensor was based on monitoring specific interaction between anti-IL-8 antibody and IL-8 antigen. The morphological characterization of each electrode modification step was analyzed by scanning electron microscopy (SEM), SEM-energy dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM) while electrochemical characterization was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and single frequency impedance (SFI) techniques. Moreover, the antibody immobilization on the electrode surface was proved Fourier-transform infrared spectroscopy (FTIR) and Raman Spectroscopy. This proposed impedimetric immunosensor exhibited good performances with a wide linear in the range from 0.02 pg/mL to 3 pg/mL as well as a relative low detection limit of 6 fg/mL. The impedimetric immunosensor had a good specificity, stability and reproducibility. This study proved that PHA was a suitable interface material to fabricate an electrochemical biosensor.en_US
dc.description.sponsorshipTUBITAK (The Scientific and Technological Research Council of Turkey)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [113 Z 678]en_US
dc.description.sponsorshipThe financial support from TUBITAK (The Scientific and Technological Research Council of Turkey, Project number: 113 Z 678) is gratefully acknowledged.en_US
dc.language.isoengen_US
dc.publisherAcademic Press Inc Elsevier Scienceen_US
dc.identifier.doi10.1016/j.ab.2018.05.030
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectInterleukin-8en_US
dc.subject6-Phosphonohexanoic aciden_US
dc.subjectIndium tin oxideen_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectSingle frequency impedance spectroscopyen_US
dc.subjectIto-Based Immunosensoren_US
dc.subjectLabel-Freeen_US
dc.subjectElectrochemical Immunosensoren_US
dc.subjectCancer Biomarkeren_US
dc.subjectInterleukin-8en_US
dc.subjectPolymeren_US
dc.subjectImmobilizationen_US
dc.subjectDiagnosticsen_US
dc.subjectElectrodesen_US
dc.subjectSensoren_US
dc.titleAn impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applicationsen_US
dc.typearticleen_US
dc.relation.ispartofAnalytical Biochemistryen_US
dc.departmentRektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezien_US
dc.identifier.volume554en_US
dc.identifier.startpage44en_US
dc.identifier.endpage52en_US
dc.institutionauthorAydın, Elif Burcu
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57194273220
dc.authorscopusid6506764918
dc.authorwosidAYDIN, Elif Burcu/ABA-9053-2020
dc.authorwosidSezgintürk, Mustafa Kemal/AAY-1439-2021
dc.identifier.wosWOS:000439741300007en_US
dc.identifier.scopus2-s2.0-85048268062en_US
dc.identifier.pmid29902421en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster