Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAydın, Muhammet
dc.contributor.authorAydın, Elif Burcu
dc.contributor.authorSezgintürk, Mustafa Kemal
dc.date.accessioned2022-05-11T14:48:12Z
dc.date.available2022-05-11T14:48:12Z
dc.date.issued2018
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.urihttps://doi.org/10.1016/j.bios.2018.02.017
dc.identifier.urihttps://hdl.handle.net/20.500.11776/10612
dc.description.abstractLabel-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This disposable biosensor was fabricated by spin-coating technique using star-shaped Star(PGMA) with epoxy side groups. After formation of a stable film with epoxy ends, anti-p53 antibodies were bound to these groups covalently. Stepwise modification of the electrode was followed by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies. The electrochemical performance of the immunosensor was studied by EIS. Furthermore, the antibody and antigen coupling was monitored by single frequency impedance (SFI) technique. The immunosensor showed a low limit of detection (7 fg/mL) and a linear detection range between 0.02 pg/mL and 4 pg/mL. Additionally, atomic force microscopy (AFM) and scanning electron microscopy (SEM) were utilized for monitoring of immunosensor surface at different stages of fabrication. The antibody coupling on the electrode surface was proved by Fourier-transform infrared spectroscopy (FTIR) and Raman spectroscopy. Furthermore, the proposed immunosensor had good reproducibility and repeatability.en_US
dc.description.sponsorshipScientific and Technological Research Council of by Namik Kemal University, NKU-BAP [NKUBAP.00.DS.17.114]en_US
dc.description.sponsorshipThis research was supported by The Scientific and Technological Research Council of by Namik Kemal University, NKU-BAP (Grant number: NKUBAP.00.DS.17.114).en_US
dc.language.isoengen_US
dc.publisherElsevier Advanced Technologyen_US
dc.identifier.doi10.1016/j.bios.2018.02.017
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectProtein p53en_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectCyclic voltammetryen_US
dc.subjectSingle frequency impedanceen_US
dc.subjectStar-polymeren_US
dc.subjectPoly(glycidyl methacrylate)en_US
dc.subjectConducting Polymeren_US
dc.subjectRaman-Spectroscopyen_US
dc.subjectLabel-Freeen_US
dc.subjectCanceren_US
dc.subjectBiosensoren_US
dc.subjectBiomarkersen_US
dc.subjectDiagnosisen_US
dc.subjectBlooden_US
dc.titleA disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serumen_US
dc.typearticleen_US
dc.relation.ispartofBiosensors & Bioelectronicsen_US
dc.departmentRektörlüğe Bağlı Bölümler, Rektörlük, Bilimsel ve Teknolojik Araştırmalar Uygulama ve Araştırma Merkezien_US
dc.authorid0000-0002-8716-9970
dc.identifier.volume107en_US
dc.identifier.startpage1en_US
dc.identifier.endpage9en_US
dc.institutionauthorAydın, Muhammet
dc.institutionauthorAydın, Elif Burcu
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55571487900
dc.authorscopusid57194273220
dc.authorscopusid6506764918
dc.authorwosidAYDIN, MUHAMMET/ABA-9027-2020
dc.authorwosidSezgintürk, Mustafa Kemal/AAY-1439-2021
dc.authorwosidAYDIN, Elif Burcu/ABA-9053-2020
dc.identifier.wosWOS:000428006900001en_US
dc.identifier.scopus2-s2.0-85041465626en_US
dc.identifier.pmid29425857en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster