Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDestanoglu, Orhan
dc.contributor.authorZeydanli, Damla
dc.contributor.authorCansever, Mehmet Şerif
dc.contributor.authorYılmaz, Gülcin Gumus
dc.date.accessioned2022-05-11T14:47:18Z
dc.date.available2022-05-11T14:47:18Z
dc.date.issued2018
dc.identifier.issn0003-2697
dc.identifier.issn1096-0309
dc.identifier.urihttps://doi.org/10.1016/j.ab.2018.09.016
dc.identifier.urihttps://hdl.handle.net/20.500.11776/10473
dc.description.abstractExcess urinary orotic acid excretion occurs in patients with some inborn errors of metabolic pathways such as pyrimidine synthesis and urea cycle. Thus, rapid diagnosis of orotic aciduria has a vital importance for patients. In this paper, a novel method for determination of orotic acid in urine samples by ion chromatography with suppressed conductivity detection was investigated. The separation of orotic acid from urine matrix was accomplished by using an anion exchange column with optimized isocratic eluent program which utilized 50 mM NaOH. The other chromatographic conditions were as follows: the suppressor current was 31 mA; the flow rate of mobile phase was 0.25 mL min(-1); the column temperature was 30 degrees C; sample loop volume was 10 mu L. Under optimized conditions, the limit of detection was 0.2 mu mol L-1. Dramatically elevated orotic acid concentration was observed on pathological urine samples comparing to healthy urines, as expected. There are a good many advantages of the proposed method, but using an environmentally friendly reagent free system, no organic solvent employment and its quick nature, and being a sensitive and reliable method are the most obvious ones. The proposed method, therefore, may be utilized as an alternative technique for clinical laboratories.en_US
dc.description.sponsorshipUnit for Scientific Research Project of Istanbul Technical Universityen_US
dc.description.sponsorshipThe authors would like to thank the Unit for Scientific Research Project of Istanbul Technical University for providing financial support.en_US
dc.language.isoengen_US
dc.publisherAcademic Press Inc Elsevier Scienceen_US
dc.identifier.doi10.1016/j.ab.2018.09.016
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOrotic aciden_US
dc.subjectIon chromatographyen_US
dc.subjectMetabolic disorderen_US
dc.subjectUrea cycle defecten_US
dc.subjectArgininosuccinic aciduriaen_US
dc.subjectUrineen_US
dc.subjectRapid-Determinationen_US
dc.subjectDiagnostic-Valueen_US
dc.subjectInborn-Errorsen_US
dc.subjectSeparationen_US
dc.subjectDisordersen_US
dc.titleIon chromatographic method for the determination of orotic acid in urineen_US
dc.typearticleen_US
dc.relation.ispartofAnalytical Biochemistryen_US
dc.departmentMeslek Yüksekokulları, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Hizmetler ve Teknikler Bölümüen_US
dc.authorid0000-0002-8550-0105
dc.authorid0000-0003-2477-0694
dc.identifier.volume563en_US
dc.identifier.startpage9en_US
dc.identifier.endpage14en_US
dc.institutionauthorCansever, Mehmet Şerif
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57189851629
dc.authorscopusid57189470687
dc.authorscopusid8283704400
dc.authorscopusid55623526000
dc.authorwosidZeydanli, Damla/ABB-8507-2020
dc.authorwosidDestanoğlu, Orhan/ABB-4428-2020
dc.authorwosidCansever, Mehmet Serif/AAU-8758-2020
dc.identifier.wosWOS:000450541700002en_US
dc.identifier.scopus2-s2.0-85054076301en_US
dc.identifier.pmid30267708en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster