Ara
Toplam kayıt 7, listelenen: 1-7
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ...
Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode
(Elsevier B.V., 2020)
A novel impedimetric immunosensor based on a conjugated polypyrrole polymer containing epoxy active side groups (PPCE) modified indium tin oxide (ITO) electrode was developed for detection of interleukin 6 (IL 6), a prostate ...
Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
(Wiley-VCH Verlag, 2021)
Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ...
Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
(Elsevier B.V., 2021)
In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were ...
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)
In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ...
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
(Elsevier Ltd, 2019)
A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...