An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
(Elsevier B.V., 2019)
In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ...
A novel immunosensor based on fullerene C60 for electrochemical analysis of heat shock protein 70
(Elsevier Science Sa, 2016)
This study illustrates the development of the biosensor for the determination of the heat shock protein 70 (HSP70). For this purpose, firstly the biosensor based on the glassy carbon electrode (GCE) was modified with ...
An ITO Based Disposable Biosensor for Ultrasensitive Analysis of Retinol Binding Protein
(Wiley-V C H Verlag Gmbh, 2014)
A highly sensitive electrochemical biosensor based on anti-RBP biorecognition capable to analyze concentrations of retinol binding protein (RBP) was developed. The construction of the biosensor interfaces was carefully ...
Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70
(Elsevier Science Bv, 2016)
In this study, it is aimed to design a label free immunosensor for determination of HSP70 (heat shock protein 70). Glassy carbon electrode was used as a working electrode. Graphene oxide was covered on the working electrode ...
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)
In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ...
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ...
A new methodology for the determination of enzyme activity based on carbon nanotubes and glucose oxidase
(Elsevier, 2015)
In this research, a novel enzyme activity analysis methodology is introduced as a new perspective for this area. The activity of elastase enzyme, which is a digestive enzyme mostly of found in the digestive system of ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...