Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAltan, Egemen
dc.contributor.authorÖzbaydar, Mehmet Uğur
dc.contributor.authorTonbul, Murat
dc.contributor.authorYalçın, Levent
dc.date.accessioned2022-05-11T14:36:08Z
dc.date.available2022-05-11T14:36:08Z
dc.date.issued2014
dc.identifier.issn1058-2746
dc.identifier.urihttps://doi.org/10.1016/j.jse.2013.11.029
dc.identifier.urihttps://hdl.handle.net/20.500.11776/8383
dc.description.abstractBackground: This study compared two different techniques that have been used to measure the glenoids of patients with recurrent anterior shoulder dislocation. Methods: We analyzed 36 patients who had received arthroscopic Bankart repair for anterior shoulder instability. Retrospectively, 3-dimensional computed tomography images of both shoulders were available for these patients. Two measurement methods were compared to determine the glenoid defects. One of these techniques is based on linear measurement, previously defined as the glenoid index. The other method is based on surface area measurement. Subsequently, 3 more diameters and the average values obtained from these diameters were compared with the surface measurement method. Pearson correlation coefficient (r) was assessed to determine the relationship. Results: There was an almost perfect relationship between measurement methods when the defect area was less than 6% of the inferior glenoid circle (r, 0.915; P < .001). This relation decreased and the difference became more pronounced (r, 0.343; P=.657) when the bone loss exceeded 14% of the inferior glenoid circle. The highest correlations with the actual defects were the average values obtained from 4 different diameters (r, 0.964; P < .001) and the 4-o'clock position of the single diameter measurements (r, 0.860; P=.001). In addition, 11 patients had crescent-like defects, demonstrating a relatively low correlation between the measurement methods (r, 0.679; P=.021). Conclusion: Although the best correlation was achieved from average values obtained from different diameter positions, in practical use, we advise a linear measurement to estimate the glenoid bone loss at the 4-o'clock position to achieve a high correlation between the measurement techniques. Level of evidence: Level III, Diagnostic Study. (C) 2014 Journal of Shoulder and Elbow Surgery Board of Trustees.en_US
dc.language.isoengen_US
dc.publisherMosby-Elsevieren_US
dc.identifier.doi10.1016/j.jse.2013.11.029
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGlenoid bone lossen_US
dc.subjectinstabilityen_US
dc.subjectglenoid indexen_US
dc.subjectarthroscopyen_US
dc.subjectshoulderen_US
dc.subjectPico methoden_US
dc.subjectRecurrent Anterior Dislocationen_US
dc.subjectShoulder Instabilityen_US
dc.subjectGlenohumeral Jointen_US
dc.subjectBare Spoten_US
dc.subjectCten_US
dc.subjectArthroscopyen_US
dc.subjectCavityen_US
dc.titleComparison of two different measurement methods to determine glenoid bone defects: area or width?en_US
dc.typearticleen_US
dc.relation.ispartofJournal of Shoulder and Elbow Surgeryen_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalen_US
dc.identifier.volume23en_US
dc.identifier.issue8en_US
dc.identifier.startpage1215en_US
dc.identifier.endpage1222en_US
dc.institutionauthorÖzbaydar, Mehmet Uğur
dc.institutionauthorTonbul, Murat
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid15051601900
dc.authorscopusid8143714600
dc.authorscopusid8450175300
dc.authorscopusid8526841200
dc.authorwosidOzbaydar, Mehmet/AAS-2718-2020
dc.authorwosidYalcin, Levent/AAR-9528-2021
dc.authorwosidOzbaydar, Mehmet/D-7391-2016
dc.identifier.wosWOS:000341135000024en_US
dc.identifier.scopus2-s2.0-84904804320en_US
dc.identifier.pmid24581417en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster