Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum
Özet
This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium tin oxide (ITO) sheet with a conjugated pyrrole polymer P(Pyr-Pac) and subsequent immobilization of anti-CC chemokine receptor 4 (CCR4) antibodies. Acid-substituted poly(pyrrole) P(Pyr-Pac) polymer contained a lot of carboxyl groups on its end site, which were suitable for attachment of anti-CCR4 antibodies. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were chosen to investigate electrode preparation stages and, EIS was chosen to detect the CCR4 concentration. Anti-CCR4 antibody attached biosensing surface was highly selective to CCR4 antigen, the specific interaction resulted changes in electrochemical signal. Optimization studies containing polymer amount, anti-CCR4 antibody concentration, anti-CCR4 antibody immobilization time and anti-CCR4 antibody-CCR4 antigen interaction time were studied. The developed immunosensor displayed a linear increase with concentrations of CCR4 antigen (0.02–8 pg/mL) and a low detection limit of 6.4 fg/mL. In addition, this biosensor had great reproducibility and repeatability. Moreover, the designed biosensor was successfully used for the quantification of CCR4 antigen in serum samples. The recovery for the spiked serum samples was between 98.25% and 103.99%. The suggested immunosensor illustrated a good selectivity towards some interferents including different biomarkers. This study could establish a new approach for future cancer biomarker detection. © 2020 Elsevier B.V.
Cilt
222İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ... -
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Wiley-VCH Verlag, 2019)In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ... -
Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier Ltd, 2019)A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly ...